    MEP-531a Aftermarket regulator/project

    Ran a test today, couple of hang ups, the 100w field resistor is to low, it got so hot I burnt myself on it and it melted some insulation on a wire touching it. Also I am getting a 120hz on my analog gauge vs 60hz on my multimeter. Generator worked great, provided consistent power and met the...
  2. Skyhawk13205

    MEP-531a Aftermarket regulator/project

    Spent some more time re designing. Disconnected my exciter system from the DC buss, I found out that the exciter was backfeeding line voltage onto the dc bus and using my Espar ecu as a ground path I found the Espar heater had a chassis ground of 18k ohms when the ecu was connected. I combined...
  3. Skyhawk13205

    MEP-531a Aftermarket regulator/project

    yes, that is basically how my wiring is. The exciter windings are part of the stator windings and terminate on the N side of the power windings. I would have liked to separate the exciter from the power but it is not possible without taking the stator apart. you were right about almost killing...
  4. Skyhawk13205

    MEP-531a Aftermarket regulator/project

    If I die from this project I will make sure to post the details. thanks for noticing the issue with the grounds I didn’t see the issue with the grounds when I drew up that schematic, the grounds are isolated. the DC and AC buss ground check has no continuity between the two. I was debating...
  5. Skyhawk13205

    MEP-531a Aftermarket regulator/project

    My project seems to have blown something up, I installed the generator in my camper to run the AC buss. I basically gutted the MEP-531a electronics and moved them into a control panel in my camper. I had to modify quite a bit to get it to work, the ops check was ok the generator was able to...
  6. Skyhawk13205

    MEP-531a Aftermarket regulator/project

    Hello, first time posting on the generator forum. I have 2 MEP-531a generators, I could not get either of them to work, I found that the VR does not pass the lightbulb test and I can’t get to power on. Both VR are swelled and once is cracked. I found an aftermarket VR called a EA350, I could not...