I Agree with what todds112 said, removing the C-D wire should kill all the gauges, CTIS, Horn, Ect.. It ,may not turn off the truck if the shut-off solenoid does not lose power. I am not sure if the shut-0ff solenoid is powered by the off-run-start switch or or the master power switch.
Added...
I bought these
http://www.delcity.net/store/Solenoid-Switch-!-SPST-24V-100A-Insulated-Continuous/p_743395
The important part is to tell the counter person you want a "Continuous Duty SPST 24V Relay/Switch " minimum of 75amps
All this information was very helpful, Just to add a bit to it on Emergency Bypassing or Testing.
These jumper wires are Copper 4 awg. about 6-8 inches long for main C to D terminal / 8 awg. Copper 4-6 inches for the Starter jumper Terminal B (Momentary for starter engage) They can be gotten...