  1. D

    need help with starter for my 89 3 kw 24v generator

    There should be a washer/gasket between the injector and the head. I don't remember if the glow plug has one or not.
  2. D

    need help with starter for my 89 3 kw 24v generator

    New gaskets under glow plug and injector? Spurt spurt spurt plus air should equal start. If not, then maybe check compression.
  3. D

    need help with starter for my 89 3 kw 24v generator

    If you get the spurt spurt spurt and no start then check injector and glow plug for leaks. Leak = not enough compression for combustion.
  4. D

    need help with starter for my 89 3 kw 24v generator

    When you put the IP back in did you make sure the governor lever engaged the IP properly?
  5. D

    need help with starter for my 89 3 kw 24v generator

    Did you remove the IP at any time?
  6. D

    need help with starter for my 89 3 kw 24v generator

    If there is air in the IP system then you won't get the spurt spurt spurt when turning over with the nut loose. Is it starting at all? Is the solenoid moving how and when it is supposed to?
  7. D

    need help with starter for my 89 3 kw 24v generator

    So, you have the spurt spurt spurt at the injector nut when loosened 1/2 turn and turning the motor over?
  8. D

    need help with starter for my 89 3 kw 24v generator

    It's pretty simple. It needs fuel and air to run. If you provide both and start it, it will continue to run until it breaks or until fuel or air is shut off. If you have bad fuel or if any of the 3 pumps isn't working of if the tank float is down or bad of if the fuel solenoid is bad or off...
  9. D

    need help with starter for my 89 3 kw 24v generator

    Get fuel to the red arrow. Then, loosen the fitting at the green arrow 1/2 turn and turn over, looking for spurt spurt sprut. Here is another view of the green arrow, only orange this time: Here is a side view showing fuel transfer pump and IP: I'm going on memory here and I haven't had...
  10. D

    need help with starter for my 89 3 kw 24v generator

    You have a 016B that won't run? If so you need to check: Air Fuel Compression 1. Make sure fuel is being delivered to the input side of the IP. There is a little hand lever for priming on the mechanical fuel transfer pump, IIRC. 2. Loosen the injector nut 1/2 turn and turn the motor...
  11. D

    need help with starter for my 89 3 kw 24v generator

    OK, I thought you wanted a starter for a 026C. The 026B starters are the same as the 016B. You just want a 24V starter for a 016B. 16 = AC generator output. 26 = DC generator output.
  12. D

    need help with starter for my 89 3 kw 24v generator

    026? I may have one. I have a 026 basket case but I don't know if it even came with a starter.
  13. D

    need help with starter for my 89 3 kw 24v generator

    A buddy of mine got a real sweet deal on a small cabin cruiser that the owner just had the motors rebuilt in. The owner could not get either motor to start. He got frustrated and gave the boat to my buddy for a song. My buddy studied the situation, asked a bunch of questions, and then...
  14. D

    need help with starter for my 89 3 kw 24v generator

    Injector pump and fuel pump are plunger driven and would both squirt if engine was rotated backward, I think. They might spin faster with the injector removed but with just the line cracked you shouldn't get enough bleed off to make much of a difference in compression and rotation. Wish you...
  15. D

    need help with starter for my 89 3 kw 24v generator

    Then you may have broken it. If nothing else there is a fan on that motor that will not cool properly if turning the wrong way. There really is no option for rotation here. The gen head doesn't care if it goes CW or CCW but the Diesel motor certainly does. I am pretty sure the oil pump will...
  16. D

    need help with starter for my 89 3 kw 24v generator

    SOME Diesels will run "backward". That one will not. Get the starter straight. If you were closer I'd buy it from you. You're killing me, Smalls.
  17. D

    need help with starter for my 89 3 kw 24v generator

    The transfer pump is on the side. It has the handle for priming. It send fuel to the IP which in turn sends fuel to the injector. The injector should be on top of the motor.
  18. D

    need help with starter for my 89 3 kw 24v generator

    OK. Must be the 003 that has the electric pump that feeds the filters.
  19. D

    need help with starter for my 89 3 kw 24v generator

    Most Diesels I've worked on have 17mm injector fitting nuts. Crack it about 3/4 turn. Turn the motor over. After a short period you should get a spurt, spurt, spurt. Note: Diesel injector pumps are HIGH pressure things. You don't want the line open and spraying into space. Just loosen the...