• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. G

    Mep 804A

    In case any one was wondering about this fuel float issue. After much pulling it out messing with float positions which float was on top and bottom ect. I seem to have found a combination of float and position that is working. For several days now every time I check the low fuel light is not...
  2. G

    Mep 804A

    One nice thing is that the only problem I've got with this machine is something that all I have to do to make the problem go away is unplug it. Ha ha.
  3. G

    Mep 804A

    Right!! That's why it's driving me nuts. Lol. It's a very simple device but it sure is having fun laughing at me. The end of the switch appears to be slightly dented.i don't know if that's causing issues. I wouldn't think that one float would be meant to be on top or bottom? I did figure out...
  4. G

    Mep 804A

    Well I tried a few more things. And again with it in my lap it was working. I went and attached it to the machine but with it out the tank if I rotated the float it has a spot where it drops out again (technically I guess it latches again) I could hear the relay click when I rotated it. After...
  5. G

    Mep 804A

    Well I finally decided to play with this a little more. I thought I had it figured out. I adjusted the top and bottom float stop positions and In my lap it was working perfectly. Then I put it in gnd tank and if I put it all the way down it still would act up but if I raised it inch it worked...
  6. G

    Mep 804A

    Thank you. I will dig into this more.
  7. G

    Mep 804A

    I will work on this more as I get time. It is interesting. The problem is definitely in the float switch I'm not getting false readings beyond the switch. Every time it says no fuel I unplug the switch and check the contacts in the first spot it plugs in with my meter and sure enough it's...
  8. G

    Mep 804A

    I think I started one about the 803. If I did that correctly I will start one about my 802 and 804 also.
  9. G

    Mep 804A

    Hello. Thanks again for being here and so willing to help people. Can you please help me figure out how to make a new thread? I would like to make one for each of my gens. I'm looking around on here and not seeing the make my own thread tab.
  10. G

    Mep 804A

    About these no fuel floats. Does anyone know where we can get just the float for these switches? I think the float has lost Buoyancy. Heck I would replace the switch but everyone is out of stock and I'm pretty sure its the float anyway. If I find a place to get them I will share it.
  11. G

    Mep 804A

    Of course! After posting pics like that I'm almost afraid to admit that electrical is my trade. I wasn't doing that work for money but for fun though. I considered using space heaters or heat guns but I wanted to give it a nice even three phase load. I ordered a 15kv heat kit for a furnace that...
  12. G

    Mep 804A

    Lol. I have been curious what people were going to say about my load bank. One thing nice it's a purely resistive load and very consistent. The dry sand actually worked pretty well to dissipate the heat.
  13. G

    Mep 804A

    I built an improv load bank. I posted pics earlier. I used heater coils from an electric furnace and wired them three phase and well laid them on the dirt and let them get hot. between the sand they were laying on and a breeze they did pretty good and pulled a nice even 30 amps per phase. If you...
  14. G

    Mep 804A

    While I was load testing the 804A it was throwing out quite a bit of black chunks out the exhaust. Does this usually mean that it hasn't been run in a while or maybe that it hasn't been loaded hard for a long time? The longer I left the load on it the more it seemed to settle into it. Also my...
  15. G

    Mep 804A

    Thanks for the info. I have a new addiction and it's buying and playing with these generators so I think I might end up on here a lot. I better learn the ropes
  16. G

    Mep 804A

    I haven't done that but it seems to be the only thing that makes sense. If I take it out and check it then when I put it back in it is good but the next day it's closed again. I thought maybe it had a crack and filled then sank. Thanks for confirming that that happens. Someone told me that...
  17. G

    Mep 804A

    Can we not upload videos?
  18. G

    Mep 804A

    I ran this with this load for about 30 minutes checking Temps and watching pressure ect. I just bought this not long ago and haven't had a chance to play with it and check to see if I got hurt or not. So far so good I guess
  19. G

    Mep 804A

    So I am still having the problem with the float switch. It is definitely the switch because I check the switch with my ohm meter and it is closed. If I take the switch out and move it manually it acts as it should. Hmmmm?. Aside from that I made a poor man's load Bank and pulled 30 amps per...
  20. G

    Mep 804A

    I think that's for an 802a right? I have that green also but I'm asking about the 804. Is it possible the float in the 804 can leak fill up and sink. I really thought I was on to something.