  1. ida34

    m1009 headlight problems

    RE: lights at last Do the blackouts work with the switch in the opposite position? Maybe someone installed it upside down accidently.
  2. ida34

    m1009 headlight problems

    RE: lights at last Sounds like that switch is broken. I am pretty sure the service drive position is up on that switch. If you need one I will check my Junkvee to see if I have one in it.
  3. ida34

    m1009 headlight problems

    RE: lights at last Are you talking about the switch to the right. This is the switch that turns on the service lights, blackout lights, or turns everything off. Up is service (regular lights) middle is off, and down is blackouts. With the right switch in blackout you can turn on the blackout...
  4. ida34

    m1009 headlight problems

    RE: re-fuse to lights That is probably your glow plugs going on and off. Even though the wait light goes out they still go on and off when you have first started up. This causes the volt meter to fluctuate and the click is probably the glow plug relay going on and off. Does it do it just after...
  5. ida34

    m1009 headlight problems

    If I remember right, the fusable links are attached to the terminal connector or the firewall.