• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

 

Search results

  1. J

    MEP-003a No voltage

    Yes the blowers are the same on both models.
  2. J

    MEP-003a No voltage

    Yes
  3. J

    MEP-003a No voltage

    Did T1 and T2 test good?
  4. J

    MEP-003a No voltage

    Sounds like the VR to me.
  5. J

    MEP-003a No voltage

    Your test are spot on. But you should continue to see voltage even after its started. One of the features of the unit is to be able to excite the field after its up and running. It does that with the start switch in the start position pin 27. So if the unit ever starts and you see no voltage...
  6. J

    MEP-003a No voltage

    Looking at the schematics your right Guy, L1 does not effect the exciter but I had one unit that took me 6 months to diagnose and the last part left in the output box was L1. I didn't believe that would have anything to do with the problem so I never tested it until I ran out of options. It...
  7. J

    MEP-003a No voltage

    It could be the VR not saying it is not. I think we are trying to help you from spending unneeded money on a VR, when it may not be the problem. We have all been there and spent good money a VR, only to find out it wasn't the problem. But if it is the VR I would highly recommend upgrading to...
  8. J

    MEP-003a No voltage

    That's what the TM says but its not true. Your test does take the VR out and you hooked directly into the exciter board. The VR takes readings from CVT1 and the linear reactor to determine how to regulate the voltage. So if those are not working, the voltage regulator will not work. I've only...
  9. J

    MEP-003a No voltage

    They have a linear reactor on ebay for $69 I think.
  10. J

    MEP-003a No voltage

    On A4 did you test the 56 ohm resistor? I think you may have found the problem in the linear reactor.
  11. J

    MEP-003a No voltage

    Usually when they go bad and cause your issue, you won't have a reading because the coil has shorted so I suspect its okay.
  12. J

    MEP-003a No voltage

    Yes I believe the test you're describing is direct current to the exciter board, which should result in voltage generation. In -34 there is a test setup for the output box which test CVT1, Linear Reactor, A4 (exciter board), etc. It gives resistance values for everything. Most of the time I find...
  13. J

    MEP-003a No voltage

    4 items I would check. CVT1 transformer. Big black transformer on the bottom of the output box. Its actually 2 transformers mounted together CVT1 is in the back Exciter board A4 VR. Sometimes to check the VR you can take number 17 off the VR board and tape it up. Start the unit and if voltage is...
Top