  1. K

    mpe803a

    I used a reducer and a short nipple to use it. I cut a slit in the wall of the flex pipe to make it easier to take it on and off. Hose clamp to secure it. The same piece of flex pipe exhaust is used on my 831's. All depends on which set I need to run in my garage.
  2. K

    mpe803a

    About 6 feet. It's just a temporary setup I use in the winter so I don't have to test products out in the snow and ice.
  3. K

    mpe803a

    I run mine out the window in my garage when testing products. I used Walker 40001 flexible exhaust hose. Walker 40001 Amazon
  4. K

    mpe803a

    Here.... MEP-803 TM's All of the available the 803 TM's are there. Need to hover your mouse over the various parts of the post for the different TM's
  5. K

    mpe803a

    TM 9-6115-642-24
  6. K

    mpe803a

    Make sure the wire from my VR labeled M7-I is on the correct terminal on the Oil Pressure Gauge. It should be on the "I" terminal, not the "S" terminal.
  7. K

    mpe803a

    Normally you can adjust the frequency a few Hz below 60. You'd need to post up a picture of the mechanical governor lever so we can see if it's a cable problem or an adjustment issue with the mechanical governor stops. Normally the stops are set at the factory and don't need adjusting. Post up...
  8. K

    mpe803a

    When you start the generator and hold S1 in START is the correct AC voltage displayed on the generators AC Voltmeter? What voltage does it read? Once you release S1 back to Prime/Run does the AC voltage displayed on the generators AC Voltmeter drop? What voltage does it read?
  9. K

    mpe803a

    Did you hook my VR's wire back up to K15-1? Frequency is set by adjusting the Frequency Adjust throttle cable located on the far left as you're facing the control panel. Recessed black knob. unlocking the knob and turning it will adjust the frequency (engine RPM).
  10. K

    mpe803a

    If you do replace S14
  11. K

    mpe803a

    From those readings it looks like S14 is bad. Do you have that spare S14?
  12. K

    mpe803a

    S14's socket is the same as all the other relays next to it. Here it is again
  13. K

    mpe803a

    If you had 24 volts at both K16-A and K16-B with S1 in Prime/Run and the engine was NOT running then it points to a possible issue with S14. S14 is on the far left of the row of relays. S14 is suppose to switch K16-B to ground causing K16 to pull in with S1 in Prime/Run and the engine was NOT...
  14. K

    mpe803a

    When I gave the directions on things to probe you weren't suppose to put S1 in START, only to the Prime/Run position. I gotta sign off, go do some grilling and have dinner with the family.
  15. K

    mpe803a

    I assume you heard the fuel pump running when you did those measurements? An I assume your meters negative lead was connected to a ground point.
  16. K

    mpe803a

    OK, need to determine why K16 isn't pulling in when it should. Here is the numbering of the terminals on the individual relay sockets. It shows K16 but it's the same for all of the sockets. Terminals 4,5 & 6 are closest to the front panel on the lower row of the socket. Terminals 7,8,9 are...
  17. K

    mpe803a

    We're getting closer. K16 has to pull in for the starter circuit to be enabled. Since it's not pulling the starter isn't going to work. Does K12 pull in with S1 in Prime/Run?
  18. K

    mpe803a

    You indicated that the fuel pump runs with S1 in Prime/Run so S10 is not the issue. Do this with Dead Crank in NORMAL, Emergency Off Button Pulled Out and Battle Short OFF Open the panel and with a flashlight watch K16 as you move S1 from OFF to Prime/Run. When you move S1 to that position do...
  19. K

    mpe803a

    Here is a picture of the relays with their reference designations and function
  20. K

    mpe803a

    All the relays in the row are all the same EXCEPT the far left thing that looks like a relay