  1. K

    MEP 802A M8 Percent Load Gauge Issue

    I finally found the picture of the insides of the Current Transformer that I mentioned above.
  2. K

    MEP 802A M8 Percent Load Gauge Issue

    Actually they are not potted on the inside. Someone posted a pic a few years ago of a CT opened up. Just 3 separate coils suspended by the plastic housing. ** Warning If the output of a CT doesn't have a load on it, it can generate extremely high, lethal voltage
  3. K

    MEP 802A M8 Percent Load Gauge Issue

    The correct number of turns of each wire thru the CT? For the 802 it's 8 turns. For the 803 it's 4 turns.