• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

 

Search results

  1. K

    10 kw generator mep 803a

    In looking at the fuse mod in my genset it appears to be done exactly per TB 11-6115-741-24 chapter 5.2. According to the TB all MEP-802,812,803 & 813's get the fuse mod during the Tier 1 & 2 resets which explains why newer gensets would not have have the fuse mod yet. Adding the MOV across the...
  2. K

    10 kw generator mep 803a

    It's a 1994 and came with the quad winding fuse mod already installed in it. I respecfully have to disagree. MOV's conduct in the presence of both voltage transients and steady state voltages. I believe you may have misunderstood where the MOV would be in the circuit. By having the MOV...
  3. K

    10 kw generator mep 803a

    I did some peak voltage readings with a digital scope on the quad circuit of my 802A (regulator pins 7 & 8 )during cranking and running. The worst case peak AC voltage was ~90 VAC just as it started to run and the quad voltage settled to ~70 VAC while running. I plan on installing the MOV...
  4. K

    10 kw generator mep 803a

    Regarding the Fuse Mod... Here is a link to TB 11-6115-741-24 that has the original info on the Fuse Mod, Generator Tier Resets etc. https://www.logsa.army.mil/etmpdf/files/080000/082917.pdf A bit more information after looking into this. The fuse mod is done to protect the generator head...