  1. P

    Adding a battery disconnect switch

    In a system with the 200A dual voltage alternator if you disconnect the ground leg (lead to the current shunt) the +24v side of the battery system will still be partially grounded thru the TCM so if you turned on anything that would normally be running on 24v it could still be seeing 12v. This...
  2. P

    Adding a battery disconnect switch

    Be careful if you have the 200 amp dual voltage alternator in your truck because a disconnect switch on the negative battery lead will still leave things grounded thru the mid battery connection. Remember that the TCM is powered thru that point and there is no shutoff for it. If your running...