    Voltage varies

    This time of year in Wyoming you can expect to see the glow plugs cycle for up to 10 minutes on a cold start until the engine starts to warm up. During normal cycling the voltmeter should only dip into the yellow for about 10 seconds at a a time. On warm summer days this might only last for 1 or...
  2. P

    Voltage varies

    If you have the 60 amp Leece-Neville or Prestolite alternators you have a fairly common problem. It can be caused by a couple of things most commonly worj brushes, a blown resistor, or a bad regulator. The first thing you want to do is disconnect the battery negative terminal for safety. Then...