Believe me, I am not the goto guy on generators! I am reciting what I have learned from others on here. Hint, When Guyfang or Chainbreaker suggests something, pay attention! I am an expert on engines and automotive electrical systems. Generators are a sidelight for me basically out of necessity...
When it is cold you set the unloaded running speed so the cycles are at about 61-62. Then when it warms up and you put a load on it check to see where it settles in at and adjust the rpm to bring the cycle down to 60. It is best to have a separate meter plugged into on of the outlets on the...
No big deal, When things are going bad and you need answers NOW you do what you need to do. I don't know if it says anything in the manual but do NOT run the set at idle!!!! You will burn out the regulator because it will be trying to make power from less than enough voltage which raises...
Just so you know, That know you pulled on is a vernier throttle so you can turn it to slowly adjust the throttle speed. And as Chainbreaker said, be sure to get the manuals and read through them. The operators manual especially. You want to read through that several times and sometime when the...
You say the switch is set correctly for 120 and the voltages are correct for 3 phase. You should be set for single phase for a home unless you have some strange wiring in your house and it is wired for three phase. I will assume you are set at single phase, have you checked the voltage adjust...