Hello. I finally have time to tinker with all the gens I bought. So the 831A runs nice and holds load up to about 2kw. At 2kw it acts like my 803 at 10kw. It holds it and smokes just a tiny bit. When I add say 500 watts it starts smoking pretty good and doesn't like it. If I try 3kw black smoke and stall. Kind of like if I try to run my 803 at 12kw then try to jump to 15. I'm not doing these things to my gen but the smoke and struggling remind me of that kind of overloading. I'm under rated load though. I've read about people getting these 831 gens to like 3700 watts. The TM doesn't address this issue directly. It mentions injectors and injector pump timinga bit for similar issues. I'm just wondering if anyone has had a similar problem with these and what was the fix? BTW I have it running outside right now with no load and it is not exactly perfectly smooth. Not sure how to describe it little bumps in road I guess. I did buy and install the circuit board from kloppk btw. Also I've heard check the return line. I pulled it off the injector and blew through it and it was clear but the routing seems funny pre injector pump the fuel line tees with the after injector do it seems there would be back pressure from the fuel pump. Are the fuel lines correct. On the diagram something called the orifice which could be my tee seem to be about right with the drawing. This is why I like having more than one and one of them working correctly. Something to reference. Thank you for any help.