    Electronic governor control for MEP 804B

    My apologies for the late response, I’ve got a Big move ahead of me including the MEP 804B that’s now has become a hobby I’m going to stop for 2 to 3 weeks to settle in! Thank You guy’s so much for your help! God willing we can start again in a few weeks.
  2. A

    Electronic governor control for MEP 804B

    R 14 T2 Also no voltage.
  3. A

    Electronic governor control for MEP 804B

    Good afternoon or evening, R14 T1 to ground stud has no voltage at start up.
  4. A

    Electronic governor control for MEP 804B

    Sounds good Thank you!
  5. A

    Electronic governor control for MEP 804B

    Im an idiot! I was on R1. CR4 T1 has 24v on start. CR4 T2 has 24v on start.
  6. A

    Electronic governor control for MEP 804B

    CR 4 has 24 Volts on T1 &T2 with or without S1 in START position, it gets 24 volt in AUX fuel position.
  7. A

    Electronic governor control for MEP 804B

    Hello, again TB6-8 has 3 wires on it and has 24 volts
  8. A

    Electronic governor control for MEP 804B

    I'm rained out will have to try again another day Thank You guys
  9. A

    Electronic governor control for MEP 804B

    I'm screwed up I checked CR4 T1 to T2 that's why I don't have voltage just tested it again and it has 24V CR4 T1 to ground and T2 to ground. I'll keep going and give you a heads up Thanks
  10. A

    Electronic governor control for MEP 804B

    S1-7 was 24V
  11. A

    Electronic governor control for MEP 804B

    That was easy enough CR4 T1 & T2 no voltage what size diode is this? I'll have to replace it, I do have a variety of diodes I'm not to good with the solder gun maybe I can crimp it? Thank you for helping me out that's a strat. Guy I know what it's like with the little one's. Were in FL and the...
  12. A

    Electronic governor control for MEP 804B

    Thank you, I'll go thru your steps and keep you guys posted
  13. A

    Electronic governor control for MEP 804B

    No voltage at startup between F and J
  14. A

    Electronic governor control for MEP 804B

    Terminal 1 & 3 at start up is 0 volt on VR
  15. A

    Electronic governor control for MEP 804B

    Excuse me for being so ignorant to the forums. I checked A1 terminal 7 & 8 at startup read 1 volt, terminal 5 & 6 = 5v with motor running. please advice Thank You
  16. A

    Electronic governor control for MEP 804B

    Quad fuse is installed and provides power to A1, I did a test for the AC voltage regulator per TM 9-6115-643-24 ( 4-1.1 ) h, has between 4 and 12 VDC J, terminal 10 and 11 of AC voltage regulator does not indicate 210 to 280 VAC i, does read 3000 ohms. Statement m is got me confused (easy to...
  17. A

    Electronic governor control for MEP 804B

    Good morning. When I installed A1 EBAY open box I installed the A1 fuse generator started although there was no power I checked the A1 fuse and it was good, I’ll go through schematic 5.2 troubleshooting to see if it’s a bad voltage regulator! I’ll keep you guys posted Thank You for the HELP! ps...