I have a MEP 805A genset that has 293 hours post level 2 reset. Installed a new pair of batteries and main panel was dead. I discovered both wires at CR1 were detached from the lugs. I replaced the CR1 Diode and re-soldered both wires to the lugs. Main panel now has power but I have a "no fuel"...
My MEP 805A generator had no power to the entire control panel. During troubleshooting I discovered both wires melted off the CR-1 terminals. I am assuming that the batteries were installed incorrectly at some point.
I verified the new batteries I installed are correctly wired in series for 24...