  1. DieselAddict

    Recent MEP Auctions

    The 8k and 10k both use the same engine. That fuel burn doesn't suck for an engine that can do over 10kw of power. At 50% of prime power rating (~5.5kw) the stated fuel burn is 1.7lph. That is less than a MEP802 under the same load conditions.
  2. DieselAddict

    Cut MEP-803a fuel return lines

    Good job and also good thinking about following the manual. I routinely find things assembled incorrectly on units I work on.
  3. DieselAddict

    Drash generator 35kw with 96,000 BTU A/C?

    Roger that. http://www.amphenol-aerospace.com/pdf/12-052.pdf
  4. DieselAddict

    Drash generator 35kw with 96,000 BTU A/C?

    Do you have 3 phase power available at your building?
  5. DieselAddict

    Question re: Loading MEP 802 or 803 onto M116A3 trailer

    If you don't have to lift it very high you can use an engine hoist in a pinch. Loading a 803 into the back of my F350 was a little sketchy but it did work. Lifting one a foot or two to get onto a low deck height trailer would be no problem.
  6. DieselAddict

    Question re: Loading MEP 802 or 803 onto M116A3 trailer

    I use an inexpensive gantry with a chain hoist.
  7. DieselAddict

    MEP-8xx wet stack info

    If it won't pull a full load run it as high a load as it can while maintaining RPM. If its wetstacked it will smoke a lot. Once the smoke clears add load till it stumbles then back it down a bit. Repeat this pattern till it will handle a full load. Don't forget to let it cool under light load...
  8. DieselAddict

    MEP-8xx Battery Information

    The biggest issue I've had with the lawn batteries is most of them today are crap. They have internal discharge issues and if you don't keep a trickle charger on them they will die and sulfate. I find that at least half of the batteries I buy have self discharge issues. The lawn batteries...
  9. DieselAddict

    Recent MEP Auctions

    I've pretty much given up on the generator hobby from the buying and selling side. I figure I might be able to offer service as more of them get out into the wild.
  10. DieselAddict

    MEP-003 malfunction

    Careful what you wish for! :D I'm going to be in China for September. I'm hoping to make a run through Europe next year.
  11. DieselAddict

    MEP803A Resistor - Diode Assembly

    They provide balancing loads for the over current system.
  12. DieselAddict

    803 Bogs Down and dies at 85% Load

    I hate that you are having to go through all this BUT your work will be a boon to others that need to travel the same path.
  13. DieselAddict

    Mep-805b 480V operation

    I think at issue is the difference between rating and capability. The rating is 416v. If you are going to operate it per norms for power delivery the voltage needs to be within 5% of the rating. That would certainly exclude it from being run at 460-480 range except in unusual cercumstances. That...
  14. DieselAddict

    Using MEP-531A in light rain?

    My weed eater does not like Rotella but it seems to really like Mobile1. Go figure.
  15. DieselAddict

    Mep-805b 480V operation

    To run the higher voltage means you are running the exciter coils harder (I'm not a fan of that). You are stressing the insulation a little more (not that big a deal). Also your overload protection will be out of whack (not good). If it were me and it was needed for a short term emergency I...
  16. DieselAddict

    Acquired a Military surplus load bank

    I've been trying to snag a real load bank for a number of years. The struggle is real {sigh}
  17. DieselAddict

    MEP-803s and UPS loads

    Either method is a compromise that reduces the total energy the alternator can deliver to the load. In my opinion I prefer the zig-zag due to all the paralleled windings being in phase with each other. With the double delta you are summing two windings and paralleling it with another. If all the...
  18. DieselAddict

    803 Bogs Down and dies at 85% Load

    That is what I'm talking about. You need (as it shows in the diagram) to measure at the top and bottom of travel. Don't measure outside the area where the rings move in the cylinder. I personally do top, middle, and bottom. That also confirms the taper in the cylinder. Make sure the minimum gap...
  19. DieselAddict

    803 Bogs Down and dies at 85% Load

    Did you check the ring gap?
  20. DieselAddict

    MEP-803s and UPS loads

    These generators in reality have several different ratings. The ultimate short term power rating is all about engine power. That is why they will go above their rating. Because the engine has enough power output to keep swinging the load. The long term power limit is more about thermal...