Search results

  1. B

    range adjuster screw

    ON a 802a what does the range adjuster screw on the voltage regulator do. does it raise or lower the maximum voltage output of the unit when the potentiometer on the control board is turned to maximum ? thanks
  2. B

    mep8o2a low oil pressure shut down

    the more I think I know about this gen the more I find out I don't. hope this makes sense to someone. reading a thread recently that talked about starting sequence to get oil pressure up before releasing the start position made me take a second look at the wiring to the oil pressure switch...
  3. B

    voltage drop

    will it hurt my mep802a if I up the voltage output at the generator to compensate for voltage drop between the gen and my house panel. 150' or so
  4. B

    connecting to a house panel

    as I understand a lot of generator connections are by extension cords. where should the main bonding jumper be located when your generator is connected to your house panel by a cord attached receptacle connection . leaving the main bonding jumper on the gen will allow a parallel path if a...
  5. B

    mep802a what is too much

    i read many posts of gens running way over 100% of their rated load in an attempt to cure wet stacking issues. the electrical end is protected by overload protection but not so for the diesel. can you break the diesel end by this practice
  6. B

    mep802a oil gusher

    everything looked fine. gen ran and held a 100% load for 2 hours. so I changed the oil, used 5w40 as if is cold here in virginia. ran the engine with new oil and decided to check for blow by by removing the oil dipstick. mist and oil spray came out of the tube. I had done this check before...
  7. B

    mep8002a IP fuel rate adjustment

    In reading the TM's and threads it seems it would be prudent to check and adjust the IP's fuel rates to mitigate my units excessive vibration. Seems like an easy procedure, take temperature reading of all cylinders at exhaust manfold location, loosen the pump's retaining clamp, the nut to the...
  8. B

    understanding my new mep802a piece by piece

    I have read the applicable TM's and still need clarity on several issues. the sole function of the fuel solenoid is to open and close the fuel supply, I assume the black plastic knob that is part of the slide assembly is to provide a point to manually close the solenoid valve if the...
  9. B

    fuel tank won't drain

    I thought I would drain the fuel tank on my new 802a but nothing comes out. the p-cock appears to be functional, I can verify it opens and closes. unit came with new filters and diesel that looked and smelled fresh. unit runs ok but like others have noted its vibration issue is work in progress.
  10. B

    mep802a max voltage setting

    my max adjustable voltage setting is 245 volts. should it be higher , if so what could cause this