    Mep-002a a1/k1??

    I like to tell folks that I talk to myself because I enjoy having conversations with highly intelligent people LOL
  2. C

    Mep-002a a1/k1??

    Well some moron actually wired the relay incorrectly switching A1-2 Ground with A1-4, it did fry one side of the contacts, that's why it would start but not continue to run when I got it,now it will start with the relay installed in ether direction but will continue to run only when installed in...
  3. C

    Mep-002a a1/k1??

    OH WAIT, I can just reverse the leads on A1- and A1-2, be back in a minute
  4. C

    Mep-002a a1/k1??

    Wow, I just figured out there is an internal diode across the coil of K1 and what would be a perfectly symmetrical relay that could be plugged in ether way can only be installed in one direction or the diode across the coil will short the line to ground tripping cb2, but plugged in correctly the...
  5. C

    Mep-002a a1/k1??

    It seems I have allot of conversations with myself here, not sure if that would be considered normal,,,LOL the diodes are under the "mount" for K1 all part of A1
  6. C

    Mep-002a a1/k1??

    OK so it appears that K1 and A1 are the same thing, only A1 has many more wires than the prints show also the prints show things like A1-5/A1-6 AND A1-7/A1-8 as diodes If the relay is installed it blows CB2 as soon as the run switch is turned but it is not anything to do with K1 marked as A1-3...