  1. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    Try opening the -24 TM, and look at the troubleshooting diagram. You are creating a problem here. Working on two gen sets in the same thread. No one, not even you, can keep track of what is what now.
  2. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    Where is that sending unit for the oil pressure gauge located? The diagram on the inside of the door does not really show anything, and there's no photos on the TM. 4X4, Please stop posting the same question in more than one thread.
  3. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    There is nothing writen on the fuse to say its not to be used for VDC, or ONLY VAC. Fuse is a fuse.
  4. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    Yes you can. Sometimes when we were in the field, of the supply system took too long, we did that until we got the real deal.
  5. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    I always wanted to convince the CECOM to go to a pop out Circuit Breaker, like CB1. Made more sense to me, then fooling with that silly glass fuse.
  6. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    Or use a multimeter?
  7. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    Ray, your right, thats the way it looks. And hooking up the batteries could blow the CR1. I keep thinking of the old sets, and there is no diode in them.
  8. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    But CR1 has not much to do with panel lights. Still, it needs to be checked.
  9. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    Are you going back to fix it? Or taking it with you?
  10. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    you need a meter.
  11. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    I would go to MT4, the battery charging ammeter next to look for power. Thats in the control panel.
  12. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    Its 00:03 here, so I may need to bail out soon. If you can keep an eye out Kurt, it would be nice.
  13. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    Do you have a multimeter?
  14. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    S17 is the big red switch on the panel. Pull it out. Put the S10 in the normal position. It has CRANK, OFF and normal. First try the CRANK position, it should turn the engine over. Then put it in the normal position.
  15. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    First tell me you have pushed in the CB1 circuit breaker in the control panel. Then check the S17, emergency switch on the control panel. Then check the S10 Dead crank switch on the left side of the set, to see if its in the right position. If you push it to crank, will the engine crank...
  16. Guyfang

    I'm an idiot!!! - Fermont MEP-802A 5kW

    Have you taken them out and put them in right?