    MEP-002a Wont Start

    Ok got some time to work on the generator today. I opened front of control panel and ac output box. Everything inside looked brand new not even any dust. I started the generator and jumped 12v to t3-5 and t3-6 and it made power at receptacle and output lugs. I than shut it down and restarted no...
  2. R

    MEP-002a Wont Start

    Ok went outside started generator and held start switch for 10 seconds after starting. No power at gauges, outlet, or lugs. I read in the TM that I need to apply 12v to f3 and f5 if I remember correctly. I will have to put more time to it later after taking granddaughter sleigh riding. Racky
  3. R

    MEP-002a Wont Start

    Thanks for the the help I got it running. I found a sticky plunger I was able to work it back and forth with some LPS1 put it back together and it started right up. Now It runs good but its not making power according to the panel gauges. I shut it right down and wanted to come here for some...
  4. R

    MEP-002a Wont Start

    Thanks for replying guys. Yes I pulled hand throttle 1/2 way out I primed the filters with electric pumps.I removed injector line from injection pump no fuel. It turns over very well and no white smoke. I tried holding fuel shut down lever all the way up also when my son cranked it over. I hope...
  5. R

    MEP-002a Wont Start

    Hi everybody I just won 2 MEP-002a gensets that are NOS and were in long term storage. I finally got to work on one of them yesterday. Removed tape and plastic bags filled with oil and diesel installed batterys and low and behold no start. It turns over fine. I have oil pressure while cranking...