• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Recent content by Donaldjerome

  1. D

    Mep-003 fuel cap

    Is the fuel cap off the mep gennies interchangable with a cap off of an an m35a2? Mine are pretty cruddy, was thinking a new deuce cap could be had cheaper.
  2. D

    Mep-002 stator

    Coyote: Are you using the 6utl batts in your mep-003? If not what is the group number? 1000 ccas sound good. I have an 003 but never broke down and bought something good for it. I use (2) group 51 batts then I can swap them and use them in my 002's.
  3. D

    Mep-002 stator

    Yes, I understand what you guys are saying. I kept the batts up with the charger. I pulled my blower wheel off today and it appears someone has done a repair on my stator where harness connects to magnets. The housing that revoles around the magnets was pretty rusted along with paint which I...
  4. D

    Mep-002 stator

    I ran the generator with stator leads connected to rectifier. I got a reading of 28.2 volts on the ac setting. So this is not within specs. Before I go buy a new stator I am going to try to clean up the inside of the ring that rotates around magnets. I made up a bracket to utilize the 5/16 holes...
  5. D

    Mep-002 stator

    Thanks, I'll check it out tomorrow. I heard people talk of wiring up a 24 volt 10 amp charger in lieu of the existing system is this more practical? I quess what I'm wondering is how reliable/trouble free the oem charging system is once it is up and running. It seems like alot of people seem to...
  6. D

    Mep-002 stator

    Regulator/rectifier is brand new, I also checked out fuse and fuse holder, all is good.
  7. D

    Mep-002 stator

    I'm working on my non charging mep-002. I had removed stator wires and got a reading of 42 volts (meter set to ac) . Before I go and pull blower wheel and assume stator is bad is there anything simple I could be overlooking. When I look behind blower wheel it appears that stator has quite a bit...
  8. D

    Mep-002 voltage regulator (D.C)

    Whoa... I looked at that pick you posted my red wire was all the way to the right IIRC. The wiring diag I have show it to be on the far right also?...
  9. D

    Mep-002 voltage regulator (D.C)

    I came across an old post which had a wiring diagram of it. I should be ok now.
  10. D

    Mep-002 voltage regulator (D.C)

    I have a new voltage regulator I am going to be wiring up to an mep-002. I can see that the top two wires go to the fuse located by injector pump. That leaves three wires at the bottom. One has a red label on it, my question is does it matter which order the remaining two wires get put on ? They...
  11. D

    Mep-016b voltage reading

    I checked the batteries with a multimeter with the set running and I'm getting a reading of 30 volts. I'm thinking thats quite high. Whats the norm for these sets? I checked the technical manuals nothing for the mep-016b. I proboly can get one from delks but it would help if I knew where its...
  12. D

    Mep-016b hertz guage readings

    I will purchase a Kill-A-Watt good idea
  13. D

    Mep-016b hertz guage readings

    When I start my mep-016b up I let it warm up then dial it in to 60 hzs via the fine throttle knob.. I plugged our chop saw in the shop to the convienance outlet when I start the saw up and put a load on the generator the hertz guage pegs out all the way to the right 64-65 hertz. Is something...
  14. D

    mep-106b lugs

    Jbk Whats the best set up for aux fuel connection? Should I set up sometinthats goes to a barb fitting so I can connect rubber fuel line or is there a better way?
Top