• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

 

Recent content by Racky

  1. R

    Death Wobble

    No question is stupid ! This has been covered lots of times just do a search. All of the info will point you in the right direction.
  2. R

    MEP-002A oil drain wrench

    Vise Grips are much better than pliers. To bad their not made in the USA anymore.
  3. R

    MEP-002a Bad Voltmeter ?

    I got some time to work on the generator today. I found a bad voltage selector switch. Im good to go. Thanks Again Racky
  4. R

    MEP-002a Bad Voltmeter ?

    Yes sir it is at 3:00 when I use the multimeter I get full voltage from the service outlet and at the wire lugs LO, L2, L3, 120v and 240v respectfully. I am also able to adjust voltage with the reostat on the control panel but the voltmeter still only reads 120v and fluctuates when reostat is...
  5. R

    MEP-002a Bad Voltmeter ?

    I installed another known good voltmeter today and it only reads 120 volts. After that I gave up its just too hot.
  6. R

    MEP-002a Bad Voltmeter ?

    Well I did it again. I bought another generator. This one runs good and puts out power. The hertz gauge works but the voltmeter doesnt. I have power at the 110 outlet and 120 & 240 at the lugs. Has anybody run into this before ? As usual all help is greatly appreciated.
  7. R

    conversion of 4 batteries to 2?

    Like emr said maintenance is key. A battery maintainer is also key. I have 2 group 31 batterys that are 5 years old and still going strong. Racky
  8. R

    MEP-002a Blue Smoke

    Well I took the injectors out and installed them into my other generator and the problem traveled with them. So now I have to wait till monday afternoon to get the injectors to the shop. Racky
  9. R

    MEP-002a Blue Smoke

    When I took the pump apart it had a very light varnish coating inside . I am going to make a educated guess that my injectors are the same. I will be removing them later today to take to the diesel shop. I hope thats it if not I will pick his brain. I will keep you guys in the loop. Racky
  10. R

    Soft top separated from plastic channel

    jjb Im over here in South Brunswick same thing happened to me and my neighbor restitched it for me. He does canvas work if you are willing to take a ride. I can ask him if he would do it and how much. Racky
  11. R

    great place for my butt

    Awesome right place right time. Racky
  12. R

    MEP-002a Blue Smoke

    I put it all together it smoked at first than cleared up. I was letting it run without a load while I was cleaning up the tools and it suddenly shut down. It was very hot cooling shutters were wide open. Well tomorrow is another day. Racky
  13. R

    MEP-002a Blue Smoke

    Ups just delivered my parts that was a pleasant surprise.Going outside to finish this generator. Racky
  14. R

    Preamble to yet another WC brought back to life

    Subscribed Racky
  15. R

    MEP-002a Blue Smoke

    Epitts yes that is the part I found broken also Gimpyrobb hooked me up with a new one. I finally got back to the generator tues afternoon. I let it run under load it still smoked the exhaust actually burned your eyes standing a fair distance away. So I decided to recheck the pump timing guess...