• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. T

    Generators and Amateur radio

    Thank you!
  2. T

    Generators and Amateur radio

    Only have a 40 meter dipole. I use to be on 75 meters signing in on 3.905 Old Buzzards net. But got into a disagreement with a few and left. Cut my dipole back for 40. Nicer people on 7.191
  3. T

    Generators and Amateur radio

    North Central PA in Tioga county
  4. T

    Generators and Amateur radio

    Hi guys, I was wondering if any of you are licenced Amateur Radio operators? I am N2MIR. I work 40 meters and wondering if there are any talk nets that discuss trouble shooting generators? Or any hams who would like to just chat about technical problems over the radio?
  5. T

    Modified remote controler

    Hello fellow 802/803 lovers, I just had a special built remote start board by Kurt Klopp. The change made was adding CT's to the C1 and C3 connection wires so that actual currents could be read instead of the % load. This enables me to balance the load by monitoring via WiFi. No need to run...
  6. T

    MEP-802a walking on smooth concrete floor

    Just a word on diesel engines that are not anchored down. From what I have been told by the experts a floating diesel is bad for it's health. It has something to do with internal vibration harmonics.
  7. T

    voltage drop

    Up the size of your cable to prevent a drop. If your using #6 you should not see much of any drop at only 150'.
  8. T

    Frequency Fluctuating on MEP802

    Yes thanks i just ordered one today
  9. T

    Frequency Fluctuating on MEP802

    If one has a bad freq transducer where can you buy a replacement? My Mep803a also has a bouncing meter. But the Fluke reads fairly steady with some digital fluctuation.
  10. T

    Frequency meter erratic

    Engine runs steady. My fluke shows very little change in freq.
  11. T

    Frequency meter erratic

    It bounces from 60 to 80 and sometimes down to zero. Its not a steady fluctuation. Sometimes it stays at 60 for about 5 seconds.
  12. T

    Frequency meter erratic

    Thank you, I will put that in my notes for future reference.
  13. T

    Frequency meter erratic

    My other analog meters are close in reading compared to the fluke. Its just the freq meter that is crazy.
  14. T

    Frequency meter erratic

    Thank you! I will go through the test proceedure. Love
  15. T

    Frequency meter erratic

    They are all tight. What switch controls the meter? I assume its direct wired to its pickup.
  16. T

    Frequency meter erratic

    My MEP 803a has an erratic. Frequency meter. My Fluke meter reads steady freq. So what is causing the analog meter on the panel to be erratic?
  17. T

    Wiring an ATS to the MEP803a

    Thank you Sir. I sent you an email.
  18. T

    Wiring an ATS to the MEP803a

    Does your board offer the time circuit to operate the pre-heaters, primer, befor the start closure?
  19. T

    Wiring an ATS to the MEP803a

    MEP 803a. I thought I had it in the post title.
  20. T

    Wiring an ATS to the MEP803a

    I plan to install an ASCO ATS. Does anyone know what the wire taps are on the 803 control board to wire the start sequence? Or is there an option kit to convert to ATS control?