Anyway, have connected a new temp sensor.
It showed me 4.6 Ohm @ 11 degree celsius.
I hope this is ok so.
Taking the sensor in my hands, decreases the resistance.
Put the card back, with the same result, WAIT lamp is on, but no ground on the light blue cable
Do I miss something, or is the card...
Hey guys,
my name is Eduard, 41, from Germany, a big fan of the US CUCV's and restore my M1009 since almost 3 years and try to manage the rest of the time with my kids and wife 8)
Here since 2012 as a 'silent reader', love this forum and now wanted just to introduce me :mrgreen:
Thank you and...
Hello friends,
done today some measurements.
1) Connected the ohm meter to the ground and to the light blue cable, which is normally sitting on the glow plug relay.
Then switched the ignition on.
Ohmmeter showed me 0 Ohm, WAIT light went on and didn't go out anymore, till I disconnected the...
Have connected a new temp sensor 'BECK/ARNLEY 1580536'
This guy showed me 4.6 Ohm @ 11 degree celsius.
I hope this is ok so.
Taking the sensor in my hands, decreases the resistance.
Anyway, put the card back, with the same result, WAIT lamp is on, but no ground on the light blue cable
Do I...
Hi friends,
done today some measurements.
1) Connected the ohm meter to the ground and to the light blue cable, which is normally sitting on the glow plug relay.
Then switched the ignition on.
Ohmmeter showed me 0 Ohm, WAIT light went on and didn't go out anymore, till I disconnected the...
It looks like, i dont have enough rights to reply here.
I will try anyway.
Thank you guys for your help.
Will check today evening the continuity of the light blue wire.
Thank you guys for your help.
@319cssb, i need to investigate, what the costs would be, to sent it from here to you.
@antennaclimber, you mean following procedure, please correct me, if i'm wrong:
1) Disconnect the light Blue wire from the GP relay
2) Connect the ohmmeter to the ground and to...
Hey guys,
I have the following situation with the glow plug system:
In my garage it is around plus 10 celsius degree.
1) switch on the ignition