• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. 86humv

    Camotek Systems

    Great product...I have 5 of them....one is serial number 002.
  2. 86humv

    VIC-3 intercom cable hookups

    Works fine not looped.
  3. 86humv

    HMMWV won't start, transmission light is on

    camo box....best out there.
  4. 86humv

    Windshield de-icer

    Those things were removed from service....problems with staying on and de-laming windows.
  5. 86humv

    Can you verify these glow plugs to be Wellmans?

    look real type. Check with Ohm meter...1.0 to about 3.0 are good. If no reading or all 0000....then bad. If they read good, then start box or TSU are bad.
  6. 86humv

    Wait light stays on, crank but no start.

    54B is on the eng. side connector pin A at start box. 54B goes through start box....and out through pin B wire 29c of body harness to start switch wire 29 A.
  7. 86humv

    M1097R1 Won't Start

    Ohm check glo plugs...1.0 to about 3 ohms...anything different like 0000 or no reading...then there toast. If toast then your box fried them . If you have a PCB box....those are real old and have been updated to EESS, and then to S3 smart start. The last two use a TSU controller in water...
  8. 86humv

    Wrapped up belt.... first steps

    I had an A/C pump frozen ..belt was still on...I rotated motor with a big wrench turning the Alternator. A/C pump no rotate, but everything else did by hand after removing belt tension.
  9. 86humv

    WTK Fan Shroud fitting

    I have the Q.D. end for your hose.....there are two types...they will not interchange.
  10. 86humv

    Smart box question

    If you have a silver label black KDS....they are not a good unit...and they only work with a GPC 12338772
  11. 86humv

    Wait light stays on, crank but no start.

    11 a/b constant volt 15A constant volt 54A from inj pump to 54B on start box eng conn. 29C from start sw. to Start box body conn.
  12. 86humv

    WTK Fan Shroud fitting

  13. 86humv

    Glow plugs roasted

    Glow plugs roasted on an open fire.....Jack frost won't let it start......
  14. 86humv

    Parasitic draw on batteries

    If the truck has the 4 spd. trans..... The relay in the panel behind batteries do fail on with ign. switch off. If trans light works, and if relay fails on....light will be on with ign. switch off.
  15. 86humv

    TCM warm to the touch, No shift, Illumination light stays on

    The relay in the panel behind batteries do fail on with ign. switch off. If trans light works, and if relay fails on....light will be on with ign. switch off.
  16. 86humv

    Who here bench tests EESS boxes?

    I have the test box Camo made. I can test boxes.
  17. 86humv

    Fuel Injector Pump Leak on a 6.5L HMMWV

    Hummer H1 mech's ....look for them also.
  18. 86humv

    Fuel Injector Pump Leak on a 6.5L HMMWV

    Do you have a 3 spd. truck...what model on data plate ? I have a few rebuilt pumps.
  19. 86humv

    Front differential alignment

    Front is offset from factory
  20. 86humv

    54 Pin Plug wire diagram needed

    74a power goes through the nuetral safety sw., the to start box....then to starter
Top