Added my dawg washer.
I've sealed all holes that I cut in the hab with Flexseal.
Honestly, spray bed liner would have worked. Best I can tell, they are the same product (one just cures harder).
Cut, sealed, and mounted the fridge vents.
The upper one has 200mm 12v exhaust fan...
Yep, the main tank drain will remain plugged until needed. The temporary down spouts will both have caps with screen.
I'm also screening the two vents behind the fridge.
The plan for the hot water pre-heat loop is this:
The system is basically a closed loop. Since no water is being released from the system, the main pump won't come on to circulate water thru the loop/heater.
Adding a solenoid diverter valve and a small pump to the loop should do the trick...
Got everything under the counter up to the actual level it will be assembled. Added my hot water return from the shower (missing the check valve), added cutoffs for the sink lines (yeah, that one red handle on the blue line triggers my OCD). LOL
Went ahead and cramped the assembly together...
For "above the fill line" stuff (like the drop in, you can get away with it. But anything below surface level should be glued in place (or welded if a metal tank).
Both the grey and black tanks given to me for the build have soft seal grommet-type inputs on the upper face of the tanks.
Thanks.
Yeah the drawing is pretty rough obviously and that previous picture was just a mockup. The tank strainer is before the pump (in this pic you can almost see it center/far right tucked behind that outlet silencer loop on the wall, but it's on the pump inlet feed). Most all of the...
Man, those little plastic check valves are junk. Snapped on in half just handling the section of PEX that it was installed in "No problem, I'll just order another pair". Then I snapped the second one in half just picking up the other 12" run.
So off to fetch some nice sturdy brass check...
Starting to lay out my pex runs....
Need to strap the main water tank
Need to run in a temp 12v and 24v
Need to cut the two vents for the fridge
Need to cut out rear external water outlet (outside shower/hose)
Need to cut out the three drain holes (tank, sink, shower)
Fish are calling and my...
Not mine, of course....
" Up armor camper the hole thing is covered in 3/16 AR plate has a big cam Cummins 400 and a Eaton road ranger 18 speed, 4 wheel steer 8 wheel drive I have a lot of parts to go with it spare bearing and seals for the axles and replacement parts for the motor and 3in...
Yeah, until I settle on a tank build it's going to ground. I'll only have gray water discharge with a 5 gal tank (won't settle on location until I do my underbed boxes on the sides of the rig). The toilet will be a Laveo, so no black tank (but for now I just have a portable camp crapper for...
Yep, everything (including the heater) is above the drain port on the tank and drain.
And at the back of the truck (at the entry/deck) I have a cold water outlet with one of those little outside shower head/coiled hose (for washing sand off dawg and feet). It's standard hose thread and I'm...