• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. G

    Mep005 no power

    Guy fang, sorry it's been a while since I contacted you last. I've been out of town with work. I actually bought a new relay box brand new with red plastic caps on it so I'm assuming the A5 card is good in there. I still have no power. I checked TB-16 for ac voltage. When I was starting the...
  2. G

    Mep005 no power

    That is great to know. Yes last time you worked with me it was the S9. Is still super grateful for that
  3. G

    Mep005 no power

    Awesome thank you very guys!!!. Guyfang, In your opinion should I pull out the a 5 card? Does that look like the culprit?
  4. G

    Mep005 no power

    It looks like you're thinking it's the a 5 card. I don't have a 400 Hz supply. And it is that a 400 Hz unit. Should I disconnect all the wires from the a 5 card and take it out To do the testing. Thank you again for your time sir.. You're a true asset
  5. G

    Mep005 no power

    Thanks for all the great info! I took out the a-5 card and nothing was burnt or abnormal. I have then hooked up all the cannon connectors. I tested a5-2 To ground DC voltage. 0 Volts... I then tried a5-13 to ground dcv. I have 24 volts while starting. Is it still the S9 Speed switch...
  6. G

    Mep005 no power

    Is this the 827 special relay?
  7. G

    Mep005 no power

    Hope you had a good holiday. Happy New Year. And thank you for your reply! I found the terminal board with the 4 wires Back connect the generator set to the static exciter. I checked AC and DC. between the terminals. And each terminal to ground. A couple of times I've got a 2 V read out but...
  8. G

    Mep005 no power

    1st off merry Christmas! Guyfang .... You've helped me in the past And you've been a lifesaver. I have a new problem. Gordy1ID New member Hi there sir. I'm having a new problem and I'm hoping you're still around to guide me through it. I have an MEP005A. About a year ago it was running...
  9. G

    Static Exciter for tge mep005a generator

    For heaven's sakes you're a lifesaver. My family was originally from Germany. Last name is Zemke. I believe the last couple letters may have been played with when they got off the boat to America. Let me give you a very big thank you bud. We all appreciate what you donate. You guys have Home...
  10. G

    Static Exciter for tge mep005a generator

    I found my problem. I replaced the speed switch i think. Left front of generator, seats in the side of the block with a Cannon plug on the top. The plunger/ cam piece on the inside was broke. I have a parts unit on-site So now the generator starts up and delivers power immediately like...
  11. G

    Static Exciter for tge mep005a generator

    Thank you again for your reply. I removed the J 9 Cannon plug and tested the D pin (bottom pin) to the frame of the generator while somebody started the generator and held it in the start position. I did not get any DC voltage. Just to be clear I wasn't sure if I should test the wire harness...
  12. G

    Static Exciter for tge mep005a generator

    Hi there thanks for your response. After I start the generator there is no voltage until I excite the field with a battery. Everything looks good in the voltage regulator and static Exciter. When I start the unit I don't get any voltage out of the static Exciter on pin A + B. On the Canon...
  13. G

    Static Exciter for tge mep005a generator

    I have to excite the static field Whenever its started
  14. G

    Static Exciter for tge mep005a generator

    Hi there. Does anyone repair the circuitry the static Exciter box? I believe i have it narrowed down to this box. Would anybody happen to have a used one? The part number is 30554 72 2605. Mep005a thankyou! Gordy
Top