• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. Triple Jim

    using home heating oil in military diesel gensets

    Hey, I live way out in the country! :-D
  2. Triple Jim

    using home heating oil in military diesel gensets

    Good advice, except the line diameter will not effect pressure difference from the tank to the pump. That is defined as the liquid density times the difference in height (head). #2 fuel oil's density is listed as 57.4 lb/ft³. Dividing by 144, you get very nearly 0.4 psi per foot of lift. If...
  3. Triple Jim

    wet stacking or idling my Mep-003a

    Yes, I understand, and I did say that I don't recommend running it under 1800 rpm because there may be reasons like reduced engine cooling, and there's no good reason to do it. I'm just saying that everything I've done to test the regulator in the 002A and 003A has proven that no extra stress...
  4. Triple Jim

    wet stacking or idling my Mep-003a

    After all my testing, it's still being said that running an 002A or 003A under speed will hurt the AC regulator? The regulator has less work to do when the engine is running under 1800 rpm in these two generators, not more. I've measured the regulator output current below 1800, at 1800, and...
  5. Triple Jim

    MEP-002a Troubles and Diagnostics

    I'm sure you can use any of the 1N400x series diodes (x=1,2,3,4, etc). Personally I think I'd drill the holes if necessary, and use 1N5408 diodes, rated for 3A at 1000V. They're dirt cheap and would be unlikely to blow again.
  6. Triple Jim

    MEP-002a Troubles and Diagnostics

    The pumps are a big solenoid, with the iron slug being the piston. The connection to the solenoid is normally closed, and when the piston moves, a switch opens, and a spring returns the piston. The pump's output is during the spring return stroke, so the output pressure is determined by that...
  7. Triple Jim

    Need T2 for MEP-003a

    Just run your 002A and measure the secondary voltage. The primary should be 120. The current rating is small, well under 1A. I was not able to find T1 at a reasonable price, so I used a generic multi-tapped transformer. You can also measure your T1's secondary voltage while the generator is...
  8. Triple Jim

    DC charging system stator overproducing

    Ok, it's still on the to-do list. :)
  9. Triple Jim

    Need T2 for MEP-003a

    Yes, I thought you meant the non-center tapped one. I just checked, and the source of my transformer is not listing any more for sale. If you can't find one, I'd be happy to take the cover off my test rig and measure the output voltage. Then you can just get a generic replacement. If you...
  10. Triple Jim

    Need T2 for MEP-003a

    It's a step-down transformer that supplies a voltage signal to the regulator board to tell the regulator about the generator output voltage. Wiring it backwards makes it a step-up transformer, attempting to apply a very high voltage to the regulator board and causing a very high current and...
  11. Triple Jim

    DC charging system stator overproducing

    OK, thanks. It would be difficult to build them in low quantity here and come out much cheaper.
  12. Triple Jim

    DC charging system stator overproducing

    What did they get for the regulator?
  13. Triple Jim

    Paralleling larger MEPs

    I know you know more about your requirements than I do, but it might be cheaper to set up a soft-start for the big motor so you don't need 60 kW to get it running. 40 hp is only about 30 kW at full load.
  14. Triple Jim

    Wiring MEP-004A to two houses

    Exactly. It's possible the fuel pump contacts made enough RF noise to drown out the remote's signal.
  15. Triple Jim

    Wiring MEP-004A to two houses

    HD, are the capacitors still on your fuel pumps?
  16. Triple Jim

    Small spark when I connect the batteries on the 002?

    It would be normal to get a small spark when first connecting the battery, as the 50μF capacitor charges, even if it's not leaky. Doing it again a few seconds later shouldn't make the spark because the capacitor should already be charged. Ten milliamps will take months to significantly...
  17. Triple Jim

    MEP-003A Gen Head

    I am also interested in what you learn. The local motor rebuilding shop owner told me that it's not practical to rebuild a motor rated at less than 100 HP these days.
  18. Triple Jim

    NO Voltage or HZ reading on meters

    Any of the 1N400X series (1N4001, 1N4002, etc.) will work fine. The 4001 is rated at 50V, the 4002 100V, on up to the 4007 at 1000V. All are 1 amp diodes. They are all inexpensive and available from the usual mail order suppliers. Radio Shack used to stock them, but I haven't checked them in...
  19. Triple Jim

    NO Voltage or HZ reading on meters

    If you've determined you definitely need an AC regulator board, I have replacements at what I think is a fair price. (see signature file below)
  20. Triple Jim

    NO Voltage or HZ reading on meters

    Very true, but many meters have difficulty measuring the resistance (ohms) of a diode. Some have a setting specifically to test diodes. A simple battery and test lamp can test them just as well, once one end is disconnected from the circuit.
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks