  1. DieselAddict

    adding GFCI receptacles to trailer mounted MEP802a.

    I'm partial to a pre-built spider box if its not a budget buster.
  2. DieselAddict

    MEP - 016b

    https://www.steelsoldiers.com/showthread.php?154722-All-the-TM-s-you-need-to-work-on-the-MEP-016B
  3. DieselAddict

    MEP - 016b

    I just checked and the files open fine on my end.
  4. DieselAddict

    MEP - 016b

    Have you searched through the generator TM section on the forum? https://www.steelsoldiers.com/forumdisplay.php?121-Generator-and-Electrical-TM-s
  5. DieselAddict

    MEP - 016b

    Can you take some photos and show what you've done so far? Do you have the Technical Manual (TM)?
  6. DieselAddict

    has my MEP-831 governor magnet been adjusted?

    I'll have to check but if I remember correctly the internal wiring for the convenience outlet was pretty light. I don't think it would be suitable for a 20a circuit. I can check when I'm back home on Saturday though. If you wan to use higher current devices I do recommend using the output lugs...
  7. DieselAddict

    has my MEP-831 governor magnet been adjusted?

    That altered bolt sets the maximum mechanical governor limit. That is an important adjustment. If you aren't seeing the engine overspeed I would leave it alone for now. We can circle back and get everything tweaked in once you have some of the other issues resolved. There is a procedure for...
  8. DieselAddict

    MEP-002a Voltage Issue

    I'd be curious why it was stated that its not a good idea to run in 120v configuration. I could see an issue with making sure you could handle the fault current but otherwise its the second best choice from an efficiency choice. Three phase being the best and 240v split phase being the worst.
  9. DieselAddict

    AcuTemp Refrigerator

    I wouldn't think so. Not from just sitting around.
  10. DieselAddict

    Wiring a 50 amp 120v rv service

    Keep us posted on how it goes.
  11. DieselAddict

    AcuTemp Refrigerator

    Its taken several days for the 8lbs of ice to melt. The insulation is very good for sure.
  12. DieselAddict

    Wiring a 50 amp 120v rv service

    Let us know how it goes!
  13. DieselAddict

    Wiring a 50 amp 120v rv service

    You can. That would be one way to not be restricted by the unbalanced load limitations that comes with 240v split phase. BUT that still only gets you half of the rating of the plug. The second thing it does is put all the current on a single pair of wires. You will be loading that 6 gauge up...
  14. DieselAddict

    Wiring a 50 amp 120v rv service

    Bummer. That is beyond the capability of the 802.
  15. DieselAddict

    Wiring a 50 amp 120v rv service

    Sure, I get that. But its still a 240v setup but it will be used as two single 120v circuits. Ok, the 802 is good for 26a between L1 and L3. Your wire and everything is overkill but that is OK. So if you were in an extreme situation drawing from a single 120v circuit in the RV you should limit...
  16. DieselAddict

    Wiring a 50 amp 120v rv service

    A 4 wire circuit is 240v. The connector you are showing is a 240v connector. Where are you getting that its 120v only?
  17. DieselAddict

    AcuTemp Refrigerator

    Mine are plugged in to house power. I have let them run on battery power to test the batteries but all the capacity testing has been on AC power.
  18. DieselAddict

    Well, the addiction is true, bought another MEP-803a today!

    My wife thinks I should sell all but one of the generators. I currently have like 6. She is lucky I've not bought a big green truck. Yet.
  19. DieselAddict

    MEP-802/803 fuel return improvements

    Couldn't agree with that more. I keep a tube in every tool bag and box I have.
  20. DieselAddict

    Florida Permit/Inspection for MEP installation

    Here in NC I helped my brother replace his main panel outside with one that would accept an interlock setup. Same kind of thing. Pulled permits, power company came out and disconnected the service. We installed the new panel which included the generator inlet, breaker, and interlock. Inspector...