    MEP 831 FAQ for owners or potential buyers

    Start a new thread
  2. B

    MEP-803A frequency cable

    A Deka holds 2.9 qts. Battery distributor.
  3. B

    MEP-803A frequency cable

    It's definitely not good oxygen in air or in water isn't not good for the plates. FWIW - DRY-CHARGED: The battery is built, charged, washed and dried, sealed, and shipped without electrolyte. It can be stored for up to 18 months. When put into use, electrolyte and charging are required...
  4. B

    MEP 831 FAQ for owners or potential buyers

    I wish I had an extra unit and spare inverters to give it a whirl. The Honda parallel cables are simply piggybacked off the receptacles nothing special in the hook up. AMENDMENT NUMBER 0004 BAA 11-002 Question 8: For the baseline comparison, does a single generator operate continuously...
  5. B

    MEP 831 FAQ for owners or potential buyers

    Don't think that's applicable to a inverter driven unit.
  6. B

    Finally bought a MEP-831a

    That "smoke" isn't blue enough to be oil. I will go with unburt fuel.
  7. B

    Moderators~ Time for a Generator only forum!?

    I think everyone should pitch in a buck or two to have vBulletin upgraded to the latest version!
  8. B

    MEP-803A frequency cable

    Teleflex Vernier throttle control cable come any length you want.
  9. B

    Fuel Pumps and Fittings MEP-803a

    Beware of Chi-Com knock-offs. A few years back walbro started selling to the public trying to save their good name
  10. B

    #2 MEP 805B oh the joys

    Anytime one is doing a continuity check if you throw in a 30 to 100 ohm resistor into the mix if there's a bad connection it will fail it just needs a bit of a load in it
  11. B

    Opinions on MEP-831A

    I love my 831a. When it is not enough I throw the interlocked double breakers feeding the interlocked backfeeder in the main panel and put the 802a online. Then if I'm feeling real power hungry, I'm also wired up to run the 3.5 hvac straight off the 802a and the rest off the house with the 831a...
  12. B

    Mep 803 exhaust pipe/extension

    I went with inch and a quarter 304 stainless. 3 inch nipple two couplings and a threaded cap. Merit brass on Amazon dirt cheap. Walker inch and 3/4 rain cap also Amazon cheap. I leave the exhaust completely capped off until it's time to run then unscrew the cap and screw on the rain cap that's...
  13. B

    Fort Riley Kansas free stuff

    If anyone is near Fort Riley Kansas I have a couple beta systems fuel filters that need to be picked up there are two I would like to get ahold of one if someone could pick them up I could make arrangements I didn't realize I won them and they need to be picked up thank you. 239-204-7873
  14. B

    MEP-831A troubleshooting help request

    Yep always turn off the back feed breaker on my main as a ritual forgot to do it on the genny one day thought it was all messed up! As Quirky they maybe I really like these generators I have a 100 gallon semi tank and can run for quite a while with that being in South Florida you just never know.
  15. B

    MEP-831A troubleshooting help request

    Well I've got them both working good now perhaps it was moisture but if you don't open the contactor before you shut it down it will rev up and act funny
  16. B

    MEP-831A troubleshooting help request

    I live in Southwest Florida humid as all get-out and I have one that has no problems whatsoever I think I'm going to dig into the inverter and see what's going on with it
  17. B

    MEP-831A troubleshooting help request

    I have the exact same problem I'll let you know when I figure it out