Search results

  1. 2

    MEP501 28v to 120v

    Depending on what you want the power for, you might look for a 24V inverter to get your 120VAC. Prices have come down a lot, though I give you that a bunch of power semiconductors might not have the reliability of a copper coil. Good luck, 2Pbfeet
  2. 2

    Please recommend a transfer switch

    Perhaps it is just me, but I think that if you have, or might have, youngsters around, I would consider putting a lock on the cover of those open transfer switches, if possible, to keep little fingers out of the live contacts and wires inside. I realize that they are UL listed, and have an...
  3. 2

    802a Coolant Fault Light

    Think of it like an electric fence- you may not remember beforehand, but when you are shocked at the post, you'll be reminded. :) 😉 All the best, 2Pbfeet
  4. 2

    MEP-803A Pegs fuel gage all the way down past empty.

    I agree that it isn't an award winning design. However, it is cheap, and the design is used in lots of senders. A little gunk can go a long way toward erratic readings in my experience. Brake cleaner and a Q-tip is usually pretty effective in my experience, but I'm sure that is a YMMV item. All...
  5. 2

    MEP-831A - Huge amount of exhaust smoke

    In my limited Yanmar experience, it is unusual for an L70 engine to stutter or stumble the way yours is doing, and @FarmingSmallKubota's suggestion of the injection pump not being engaged properly, or with a bent pin/rack would certainly do it. That is an easy check; remove the inspection plate...
  6. 2

    MEP-831A - Huge amount of exhaust smoke

    Unburnt fuel looks very different; usually either clouds of white smoke (uncombusted fuel) or "rolling coal". Personally, with diesel engines, I have found that it is helpful to become proficient in the different colors of smoke and their possible causes as it can really speed up the...
  7. 2

    MEP-831A - Huge amount of exhaust smoke

    Hmmm... that looks like oil from here. Does it clear up at all? If not, have you checked the entire intake path to make sure there isn't something plugging it up? If it doesn't clear up, I would wonder about valve guides or rings being an issue, or even a cracked head, but I would check the air...
  8. 2

    802a power output issues

    @kloppk thanks! That was a nice explanation of how K8 functions. All the best, 2Pbfeet
  9. 2

    MEP 701a/Gasket Material

    @Coug thanks for the specification. Actually, I think that the specification goes further in 6.1; "Material covered by this specification is intended for use in gaskets for watertight and airtight closures. It is not intended for use in equipment dor food service or containers for potable...
  10. 2

    mep 802aoverload panel light on

    +1 on DeOxIt over other brands, and I would also second the advice to check guitar or music stores (I've also bought it there in the past), but also electronics parts stores, if you have any in the area. I would also leave the doors open, weather permitting for the generator to dry out. All...
  11. 2

    MEP 802A What happened here?

    Or hook up the wires to the terminal board incorrectly. I had that wire burned up in a generator that I bought. Hot tip: it is not listed in the TM. @Guyfang put me on to it here; https://www.steelsoldiers.com/threads/new-to-me-mep-803a-with-a-charred-ground.215947/post-2526448 10ga TGGT wire...
  12. 2

    Bought another non-running 802a, begins to start, then falls off (Now an excessive vibration fix up thread) (SOLVED)

    I agree a softer isolator set with increased sway is going to be hard on a number of things. That is not to say that the current set is the right stiffness. I've been down that path with a number of pieces of custom equipment, and I think that it is often like the old story of pulling on a...
  13. 2

    Bought another non-running 802a, begins to start, then falls off (Now an excessive vibration fix up thread) (SOLVED)

    I agree 100%. It does seem like an unusual design / specification choice, but one made repeatedly. So I'm probably missing some important design consideration. Three points alone define a plane; four takes alignment. Losing one of four mounts leaves the load well out of vibrational balance due...
  14. 2

    Bought another non-running 802a, begins to start, then falls off (Now an excessive vibration fix up thread) (SOLVED)

    I really liked your video and the analysis of your vibration issue. I found it very informative. I do not know that I would have thought of a height difference in the mounts being an underlying cause of a vibration issue, but now that you have pointed it out, "Duh!", I can see how a lack of...
  15. 2

    Mep803a white braided wire

    I'm glad it helped. Most of the ends take high temperature crimp connectors, but if you use the MIL-Spec parts, they will be fine. If you can get most or all of them as a wire harness, that sounds like a win to me. Allthe best, 2Pbfeet
  16. 2

    Mep803a white braided wire

    @hdsadey The white wire with braid is almost certainly TGGT (Teflon-Glass-Glass-Teflon, occasionally as TFFT Teflon-Fiberglass-Fiberglass-Teflon) wire, with a special insulation and temperature (450C/840F) and amperage rating. The higher amperage ratings follow from the high temperature...
  17. 2

    MEP-802A battery

    Or just slide some heat shrink or vinyl tubing on the uncoated ones? Isn't the goal mostly about reducing accidental contact? I've seen ones made out of fiberglass angle pieces, but those have to be $$$... All the best, 2Pbfeet
  18. 2

    MEP-002A Saved the Day

    I'm glad to see that fire threat is down somewhat for you. I guess my take on the generators and fire preparedness is that it is just the table stakes for living where I live. Personally, I prefer tornados (some warning) to fires (not much warning, at least around here), to earthquakes (no...
  19. 2

    How to wire a power panel right to my mep 803a generator

    For rocky areas, the MK-2551A/U might be easier to install, but it is not as simple as a ground rod, though purportedly a better signal ground. I can recommend the army grounding manual, if you are interested. CECOM TR-98-6 "Earth Grounding and Bonding Pamphlet"...
  20. 2

    MEP-002A Saved the Day

    That looks like a great score! Good luck on the fittings. All the best, 2Pbfeet