  1. C

    M1078 Battery Conversion

    We accomplished your battery conversion today on our Brush Truck following your video to the T and it worked as advertised. Thank you. Cheesehead Dave. Crooked Lake Volunteer Fire Department.
  2. C

    M1078

    When we push the Red start button the starter engages and disengages constantly (chatters). We can start it by bypassing the start system and jumping the frame mounted solenoid. we tried changing the starter relay with no change. Any Ideas?
  3. C

    M1078 start issue

    Thank you. Sounds like a plan.
  4. C

    M1078 start issue

    Found a 5 pin relay in the K1 start relay slot. Should have been a 4 pin relay. Installed 4 pin relay and it fired right up with the red button. We also did the mod on the starter to bypass the starter thermal switch (P81). Drove the M1078 for an hour. Stopped and started the engine several...
  5. C

    M1078 No Start...Not even trying.

    Does anyone know or have a picture of where the neutral safety switch is on the M1078 LMTV?
  6. C

    M1078 start issue

    Had problems starting our M1078. Bypassed red start button with another start button wired directly to the frame mounted start solenoid. After the first start, the thermal switch on the starter prevented additional starts. As suggested in a previous thread we tied the two white wires for the...
  7. C

    M1978 start issues

    Red button would not start the M1078. Ran a separate start button to the frame mounted start solenoid. That worked until we ran into the starter thermal switch problem. We tied the two white wires together as suggested and that allowed the red start button to work again. Ran into the thermal...
  8. C

    LMTV starting issues

    Yes
  9. C

    LMTV starting issues

    Could you give me a quick overview of your bypass wiring. We went to the hot side of the start solenoid back to a push button switch then back to the start solenoid with a 20 amp fuse in between. Works great. What do you think?
  10. C

    M1078 starting

    Engine would not crank. Suspect neutral safety switch. Don't know where it's at. Bypassed by running a push button switch to the remote start solenoid. Works great, but would like to do it the right way. Where is the neutral switch located? Thanks.
  11. C

    M1078 Paint

    Our fire department obtained an M1078 to be used as a brush truck. We want to paint the cab red and put our logo's on the doors. I know nothing about the paint. Can we simply sand it, apply a primer, then paint over the primer. If so, what type of paint and primer should we use. Is the current...
  12. C

    M1078 electrical system

    Our volunteer fire department is getting a surplus M1078 to be used as a brush truck. We've ordered a 250 gallon slide in pump pallet for use on it. I'm wondering if the 12V system aboard the truck has enough amperage to operate a hose real and a 13 hp gas engine starter. Otherwise I'll have to...
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks