ZOMBIE THREAD!!!!
OK so 2 years later I've "gotten round" to looking at this. It was surrounded by poison ivy and mud so I just never felt like dealing with that. Two weeks ago I did a little round up job and then waited. Few days ago I took out the dead stuff with a trimmer then put down...
I'll dig in this weekend if I have some time. Freezing rain here for the next few days. I am familiar with a DMM. I have the manual. I guess I am being a little lazy. I am hoping a few minutes of guidance will save me hours of digging in manuals. If it's a bad relay that is only used when...
Because of my VR replacement the unit does not generate power immediately. I have to hit the start a second time for the VR to wake up. The light doesnt come on until I have the unit running and making power and then hit the output power relay. Sorry I'm not using the right terms. I toggled...
I have an MEP004 that has been used very little (35hrs total). It has been updated to modern VR and exciter and converted to single phase. I have some solar so I no longer use the generator to power my house. Instead it's hooked up to an 80A battery charger and then the house runs from the...
I thought I would put up a video of the flash/avr doing its job. If anyone sees any red flags on what is working/not working please let me know. I rough set the voltage to 240v with fine adjust in the middle. That lets me adjust from 230v to 250v on the dash panel. I call this a win.
Be...
SUCCESS! I rewired it tonight and gave it a quick test run. It worked PERFECT! Better than I expected. While I help it in start mode to bring up oil pressure it slow started the voltage and brought it up to 120. Once I release starter it floated up to 240v over the next 2 seconds. Nice and...
So I just went out to take a look at the genset. The reconnection board is connected directly to the output relay and the output relay is directly connected to the output terminals. I assumed it would be more "hidden" but hadnt looked myself. I think I can just connect to L1-L3 of the input...
I have no idea. If I try to run it with the setup I have it overvolts and shuts down so I can't put a meter on things. I was hoping someone has one converted to 240v and could tell me a good point to use.
So I am trying to move to a full replacement of the Flash/AVR for my 004. I ended up buying a non-compatible flash module to go with my AVR. Exciter is 120v/240v and VR is 240v only. The instructions I am using guide me to a 120v point for output voltage detection. In this setup the exciter...
I just started digging into the manual tonight. Honestly I thought it would be like hens teeth to find a new solenoid. I was wrong. The solenoid is part 1115505 and readily available. Not super cheap but that doesn't matter so much. Debating on OEM on aftermarket. Roughly 2x-3x the price...