• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. H

    Generator charging issue

    The solid pulley fixed my issue, now I just have one more issue to fix which is the fan being stuck on.
  2. H

    Generator charging issue

    Perfect, I have one of these laying around that Im going to use, how is it running for you if you have the 200A generator? I was worried about it putting stress on tensioner and generator since its a non clutch one
  3. H

    Generator charging issue

    I've figured out, this pulley is for the newer turbo humvees only I think, the big piece sticking out is blocking it from even with the other pulleys
  4. H

    Generator charging issue

    Correct
  5. H

    Generator charging issue

    Is it safe to use on the 200A generator? I already have it and would hate to send it back, but if it can cause damage then I'll just send it back and get a clutch one. Even though my clutch pulley failed me in about a year of time
  6. H

    Generator charging issue

    Ok I got the pulley, I have a question, is this the correct pulley https://www.hummerpartsguy.com/PULLEY-ALTERNATOR-200-AMP-SERPENTINE_p_16102.html I bought this one and notice it seems like a solid pulley from the outside. Maybe its clutched on the inside?
  7. H

    Generator charging issue

    Its the correct belt but is there any chance the clutch pulley could've broke which is causing this?
  8. H

    Generator charging issue

    I'm back on this again, I notice my generator is charging perfectly at slow speeds and acceleration, but soon when I give it a good bit of gas or get on the highway and do 60 or more, the generator starts acting weird and don't want to charge properly. I cleaned all the contacts and ground and...
  9. H

    Generator charging issue

    So now Im starting to think this issue was caused by the gel degreaser, for some reason the generator started charging like normal when I was coming back home today. Its way too much of a coincidence that this started to happen the day after I used the gel degreaser. For now, I'll always use the...
  10. H

    Generator charging issue

    Batteries seems fine, I tested the volts at the regulator and Im getting 23.9 at idle and 24.5- 25.1 with the idle pulled out at the IGN post
  11. H

    Generator charging issue

    The batteries themselves are just a year old, but I'll take them out and test them
  12. H

    Generator charging issue

    My volts is at 24.9 - 25.1 on the IGN terminal, I notice it also kept between 24.9-25.1 on my inverter when I drove it home also
  13. H

    Generator charging issue

    I I'm not sure but I will take a look at it again when I go back to the storage
  14. H

    Generator charging issue

    Wow that just sucks, it looks like this thing is going be broken for quite a while, its insane how expensive these generators have gotten over just a year
  15. H

    Generator charging issue

    Well, it looks like this not going to go well, I changed out the plug and Im still getting the same results, the thing is, I am getting power to the regulator but still not getting any charge from the generator, Im going to check over all the wires and then I'll start with troubleshooting. I...
  16. H

    Generator charging issue

    Im going to do the whole plug, I have another bad generator that has good plug that Im going to just splice on and yea Im going to look through it
  17. H

    Generator charging issue

    Im just going to splice off the bad part instead of taking the whole thing apart
  18. H

    Generator charging issue

    Im kind of uncertain on this, but my generator is barely charging with my 200AMP generator. The RPM gauge either goes completely off or just jump between 0-600RPM no matter what speed the engine is at. The battery gauge is also in the yellow and close to red, and I'm only getting 25v with both...
  19. H

    Plastic Bolt Broken On Power Steering Reservoir

    Am I'm temporarily able to use a bolt till I get another sight glass? I can check the fluid through the top nut
  20. H

    Plastic Bolt Broken On Power Steering Reservoir

    Anyone know if I can just put a bolt in there or do I somehow need to find another exact piece?
Top