Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!
Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.
Spent away many a day out in the Pine barrens with 51 then 56 Chevy learning to drive. Operating that winch should be a two man job.
Play with winch last after you pull the floorboards and lube/tighten inspect everything
in there especially the forever overlooked jackshaft fittins. Those tires...
At this place in 33334 I have installed four possible feeds from the 57 gallon tank and another 100 gallons in bottles. When that runs out We will be out of need anyhow the food will all be gone. For us the propane generator, house connections and spare bottles is about an $1100. A loss that I...
sort of like this
You could load that thing with ammo and rockets and it wouldn't fail on the trail.
Best idea so far is to put a generator on it and/or a welder with all the equipment and large fuel tank.
51 one hours would have cost me how much propane on my unit?
I figuring because the reason I prepared all this back up power is because last biggie power was out for 21 daze, not to long ago.
Wife wants power on and I prepare always.
Original design is to run with minimal maintenance, supply needed power, always 100 loaded for the troops. Should serve your purposes well.
https://poweroutage.us/
I figure He has a phone and never ever did read/study the
TM 9-2320-280-34 page 2-13. might need a simple puter to see PDF.
Maybe twsitt thing or facefart other silly things gives instant answers, look over there.
California is the absolute goffiest state, probably needs to be given back to Mexico.
If one reads the treaty one finds what the problem is
I don't think Texas would have anything to do with it.
Maybe, as the Wife says, California will fall into the ocean...
I think maybe He meant so how the heck does one test a transmission control module.
Read troubleshooting TM 9-2320-280-34 page 2-13
need codes thrown or maybe it or the wires are dead and has no codes?
Here is data
also TM 9-2320-365-24P figure 247
http://trucks25tonm1078v1-5.tpub.com/TM-9-2320-365-20-4/css/TM-9-2320-365-20-4_575.htm
also TM 9-2320-365-20-4 contains all the information you seek and is big being
100mb. I can send in an email if you request.
Follows is an old Florida powerplant guy comment.
Yes, I know opinions are like those holes people speak of derogatorily.
Gee, anything computer controlled would not work here.
Puters fault due to lightning ingress to ground. Very common, very difficult to ground here. Lightning just eats its...