2 check valves per pump, normally they are blow through so a weak pump shouldnt cause a stall, there is also one in line between the filter and IP. its in the hose right by the oil pressure gauge.
Not on this series of set but i did have another piece of equipment where a check valve...
Yes thats the point. The slug seizes up, when the pump is disassembled (except the slug) compressed air in the output can be used to dislodge the slug if a solvent and tapping doesnt work.
I have only had a pump badly gummed up once to need to blow it apart.
Id say very reliable. I personally have yet to come across one that is a total loss, every inoperable pump I have had my hands on I have been able to clean out and restore to working order.
What I've done in the past when I've had a unknown gummed up blockage somewhere is take fittings apart in certain spots and judge fuel flow based off of how fast the pump is clicking. I usually go for prefilter post filter and at the injection pump. If you look at the fuel line right where...
its normally open and pressure closes it, the TM is testing a failed closed situation, your possible failure is a failing open. Jumping it takes it out of the equation.
I personally would never withhold information, I also tend to answer short and simple because i tend to ramble and get really boring.
The convenience outlet is wired before the main breaker, so the main breaker wont shutoff anything plugged in there. Its own breaker is fairly low rated (IIRC...