  1. DieselAddict

    Worth the upgrade to MEP 003a from 002a?

    I found out that a MEP003 was much too much for my all electric (except gas cooktop) house. When I tested everything out I found that I had to turn on the dryer, water heater, and oven at the same time to get the load up to 75%. A neighbor that owns a farm finally pestered me enough that I sold...
  2. DieselAddict

    10 kw generator mep 803a

    Can you post your test results?
  3. DieselAddict

    mep-803 terminal output question

    THWN-2 (90C) 6 ga copper wire is good for 75 amps. That is more than enough for a MEP803a. 75C wire is good for 65A. Still OK but closer. There is no difference in cost so why not go for 90C wire.
  4. DieselAddict

    mep-803 terminal output question

    The question about cable size got inserted in more as a comment than a question if I read the above posts correctly. As a general rule of thumb you use the ampacity table for wire lengths up to about 100'. For lengths between 100' and 250' you would go up one wire size to keep voltage drop...
  5. DieselAddict

    mep-803 terminal output question

    Thanks for starting a new thread. The total output is about 50A between the two hot wires (L1 & L3). Where this is a little tricky is that you can have 240v and 120v loads. The 120v loads won't distribute amps equally between L1 & L3. This unbalanced 120v load is carried back on the neutral...
  6. DieselAddict

    LED battle short and circuit breaker lights question

    This really needs to be its own thread.
  7. DieselAddict

    Getting an MEP803a Up and Running

    This strongly suggests you have a blockage somewhere downstream of the return line. I would suggest removing the cover over the fuel tank and disconnecting the return line at the tank. Put it in a jar and see if you get flow back through the line.
  8. DieselAddict

    802A Parallel operation ???

    The info you need on the VR board isn't in the standard TMs. The following are my thoughts on how I would do it. I offer these thoughts with zero guarantee of success and zero guarantee of not blowing it all up (or worse, hurting yourself). It is possible to seriously injure yourself and...
  9. DieselAddict

    802A Parallel operation ???

    Ok. You are right based on your description. Your voltage regulators are not playing nice together. Driving both from one regulator is likely going to damage the regulator. I don't recommend doing that. Since you are determined to parallel the generators I would recommend setting them each...
  10. DieselAddict

    802A Parallel operation ???

    That won't work the way you want. To do that right you need VRs with external biasing. PLUS... That won't fix the circulating currents. Your problem is with the governors on the generators. Not the voltage regulators. Difference in torque from each engine is the source of the circulating current.
  11. DieselAddict

    Getting an MEP803a Up and Running

    I would make a linkage. As you point out its a simple slotted bracket. If someone can measure one for you it will be easy to replicate. I'm 3000 miles from mine or I would be happy to do that for you.
  12. DieselAddict

    MEP Drawing restoration

    I'm still working on it. I'll remove the watermark as soon as its done. It shouldn't be a problem to read through it. I made it very light. Just want anyone using it to know that its not fully vetted yet. Here is the base layer without the watermark -...
  13. DieselAddict

    MEP Drawing restoration

    Your welcome. I'm part fossil myself. ;)
  14. DieselAddict

    MEP Drawing restoration

    I posted a file with everything in separate sheets. It makes the file larger but you can see things easier if your reader software doesn't support layers. https://drive.google.com/file/d/0B2ucd1TGFTw_QkZLblNsRlBIcUE/view?usp=sharing&resourcekey=0-J1RsuEKYstDFaYwCxcV_dQ
  15. DieselAddict

    MEP Drawing restoration

    Let me know if you can't do layers. I'll export everything as separate sheets.
  16. DieselAddict

    MEP Drawing restoration

    In case this makes it easier I've made a google drive link. This will always be the latest version of the file. https://drive.google.com/open?id=0B2ucd1TGFTw_b0dqdURiS3lOZlU
  17. DieselAddict

    MEP Drawing restoration

    Download the attachment in this message. http://www.steelsoldiers.com/showthread.php?159693-MEP-Drawing-restoration&p=1941339&viewfull=1#post1941339
  18. DieselAddict

    MEP Drawing restoration

    If you have Adobe Acrobat you should be able to open the "Layers" dialog and toggle them on and off with the little eyeball icons next to each layer.
  19. DieselAddict

    MEP Drawing restoration

    Can a few members download the drawing and let me know if the layer feature is working with your PDF reader? You should be able to turn off the B+ layer and make the highlighting go away. I've tested it with Adobe and it works.
  20. DieselAddict

    LED battle short and circuit breaker lights question

    It is the control power circuit breaker. It is mounted on a bracket behind the gauge panel near the center. It pops out like a turkey timer when it trips. Push in to reset.