  1. DieselAddict

    MEP-831a Troubleshooting

    I had a moment of stupidity when I started one with too little fuel in the tank. K12 was energized by the low fuel switch. Kept wondering what was going on. It was a sunny day and I couldn't see that the fuel alarm was on.
  2. DieselAddict

    MEP-831a Troubleshooting

    No alarms on the panel? Unplug the governor actuator so it will stay running. Check the voltage on the top of the inverter. Does it go out there?
  3. DieselAddict

    MEP-831a Troubleshooting

    Can you post a video of what it does when you shut it down?
  4. DieselAddict

    Calling all MEP-803A mechanics

    I've not had the chance to work on a 803 yet so I'm not going to be able to offer much first hand info there. What I can offer is that a Propane generator will eat a hole in your wallet that you WON'T like. I have a number of friends that have all found out about that the hard way. You will do...
  5. DieselAddict

    Back feeding main panel breaker questions

    I don't have anything against interlocks. Just pointing out they have more risk than transfer switches. That is all. No condemning them nor am I suggesting that they shouldn't be used. Only providing my thoughts from experience. You rightly point out that properly maintaining the electrical...
  6. DieselAddict

    Back feeding main panel breaker questions

    There are more potentially dangerous failure modes with an interlock setup versus a double ended transfer switch. I'm not at all condemning their use. I have a breaker interlock on my system. With that said if I was building a system from scratch it would absolutely have a transfer switch...
  7. DieselAddict

    Back feeding main panel breaker questions

    I agree 100% that a doubled ended transfer switch is far safer.
  8. DieselAddict

    Back feeding main panel breaker questions

    Mechanical failures are a problem with breakers. One of the things done in industrial applications is to exercise breakers on a yearly basis and load test them every 5 years. Before starting this test go to the breaker panel and feel each breaker with the back of your hand. Make note of any...
  9. DieselAddict

    Back feeding main panel breaker questions

    I don't understand the comment in this context. Jim has an interlock that prevents both breakers from being turned on at the same time.
  10. DieselAddict

    Back feeding main panel breaker questions

    You should never backfeed a panel without an interlock. While backfeeding not the preferable method it is an accepted method.
  11. DieselAddict

    Back feeding main panel breaker questions

    The breakers protect the conductors and by code you aren't allowed to install a breaker that exceeds your conductor rating. So if you are running 6ga copper then you have to use a 50a overload. To jump to a 60a you would have to use 4ga copper. That would also exclude you from using a 50a RV...
  12. DieselAddict

    Calling all MEP-803A mechanics

    I agree with R Racing that the master switch is not flashing the field. After the engine is running you can throw the master to "START" and see if it flashes? Do you have any photos of the unit you can post? Do you have the fuel cut solenoid like you see in this image (this is an 802 but similar)?
  13. DieselAddict

    MEP-831a Troubleshooting

    The meter could be off. I'll take a reading on one of mine as a sanity check.
  14. DieselAddict

    MEP-831a Troubleshooting

    This won't cut and paste nicely from the manual. Have you checked out the meter itself? 4-26 Table 4-4. Unit-Level Troubleshooting (Continued) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 8. NO READING ON KILOWATT (LOAD) METER (M2) WHEN LOAD IS APPLIED Disconnect P17 from A8 and perform...
  15. DieselAddict

    MEP-831a Troubleshooting

    What kind of meter are you using? You need one that reads microamps DC.
  16. DieselAddict

    MEP-004 run down to idle after 25 minutes, then dies - fuel system clean

    Have you checked that excess fuel is being returned to the tank?
  17. DieselAddict

    MEP-831a Troubleshooting

    I'm headed down to pick up a parts unit on Thursday. Crossing my fingers that the parts I need are good on this one.
  18. DieselAddict

    MEP-802a Battery Suggestions

    I'm using a couple of lawn tractor batteries. They are about 325 CCA and a pair was $60. They spin it over with no trouble.
  19. DieselAddict

    MEP-831a Troubleshooting

    That is very interesting. I would have thought that a head bolt would have been a finer thread pitch than that.
  20. DieselAddict

    MEP-831a Troubleshooting

    Looks like the nut is a M8. You should be able to find those at your local hardware store. Get both a fine (1mm) and coarse (1.2mm) pitch. I've not seen anywhere that info has been listed. If I was going to bet I would bet on it being a 1mm pitch. Get a higher than standard grade.