• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

 

Search results

  1. R

    Problem with Aux fuel throwing circuit breaker cb1 mep-802a

    OK, So, generator runs fine on main tank. When I set it to aux fuel it sometimes runs for a while then trips cb1 After this it will throw the breaker as soon as I turn the main switch to aux prime and run. Pump runs for about 2-3 seconds the circuit breaker trips. Thanks for any tips
  2. R

    Mep-802a aux fuel pump trips breaker?

    OK, Whenever I set the generator to aux fuel it runs for about 2 seconds then trips the breaker. House tank works fine. My theory is that the pump is gummed up maybe from the leftover sesame seed oil in my drum? Any other ideas?
  3. R

    Mep-802a auxiliary fuel questions

    Hello, Power has been out for 6 days now. I got tired of filling the tank so I went out and got a barrel. I have the military dip tube and have it hooked up. I'm about to go out and get some fuel. Do I need to open the small cap to vent? Or does the military auxiliary tube have some kind of...
  4. R

    Mep-802a. Any reason not to drive ground rod?

    Hello, I have my generator connected through a transfer switch with neutral bonded at main panel. The cable from the generator to the house is about 150 feet. Is there any reason not to also drive a ground rod at the generator? Thanks
  5. R

    Grounding Mep-802a while load testing etc

    Hello, I have the Map-802a properly grounded when connected to my house through a transfer switch. My question is when I am not connected to the house for load testing or other purposes do I need to reattach the ground strap and drive a ground rod? Thanks
  6. R

    Fuel storage and fuel transfer

    Hello Everyone, I have an mep-802a. Last summer I got the wires trenched with an inlet box and then a transfer switch inside my house. Everything is safe and working good. Had an electrician do some of the work and look everything over that I did. Now it's time for me to get ready for any...
  7. R

    MEP-802a first connection to the house, report

    Hello, I just thought I would post a report. I bought my unit about a year ago and many of you helped me with this thing so I thought I would post a report about how it's working for me. Here are the parameters 1. My house is 2500 square feet 2. I have natural gas running my stove, furnace...
  8. R

    New member Hello

    Hello, New member here. I have been reading this forum for a long time mostly interested in military generators. Planning to look for an mep002a for backup power at my house and for other emergency situations. Thanks for all the info so far about these units.
  9. R

    Looking for an map-002a

    Hello Fellas I just joined this message board after reading information for months. Thanks for all the info about these generators. Anyway, I am looking for an mep-002a. I live in south east Michigan near Ann Arbor and Detroit. If anyone from this area has one, or plans to pick one up at one...