• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

 

Search results

  1. D

    Comical stenciling on 803 GOV planet today

    Guyfang, Close to you... I joined the Airforce , October 14th, 1972., as a LEO David
  2. D

    MEP 003a wiring issue

    Guyyfang, Many thanks for the link for the updated schematic. Helped me greatly. Working on stuffing the innards back in one of the 003a's phase change box. Of course it does help when working with the CVT-1 and CT-1, it pays to know the difference between a C2 and a 2C ( also pays to pay...
  3. D

    MEP 003a wiring issue

    Guyfang, Thanks for the info. Will work on it ltr. David
  4. D

    MEP 003a wiring issue

    Hello everyone, I have most always tried to resolve my issues. This one has me over a barrel. I am replacing a 003a CVT1 and CT1 transformers. Tried to do this with them inside the output control box. That did not work as the wiring isn't long enough to do this. Ended up pulling everything...
  5. D

    MEP 002A STARTING ISSUE

    Cube, How tight are you getting the delivery valve holder? I have had to tighten the holder beyond spec on a few units to get the ip to make enough pressure to start. Also have never had to use grease to hold parts on re-assembly. They have just gone in the right place. David
  6. D

    MEP 803 Voltage Regulator

    Thanks also to the others that responded and helped. David
  7. D

    MEP 803 Voltage Regulator

    Kurt, Success! Found 24v power on the oil pressure gauge opposite terminal (one terminal counter-clockwise) with fuel pumps running. Moved wire, it started and is purring out there as I type this. Appears terminal designations are switched. Looks to be a quality constructed controller. I...
  8. D

    MEP 803 Voltage Regulator

    Kurt, I figured you would have an idea from the symptoms. I looked over M7 and did not see the "I". The wiring numbers on M7 did not line up (137Jxx). Will go over that area again tomorrow. Many thanks for the response. David
  9. D

    MEP 803 Voltage Regulator

    Kurt, Had some time today so I tackled your new regulator for my 803. Install was fairly simple. Just have one issue-when I start the unit, the power comes up ok, then when I release the start switch, the power drops off to zero. Being you have the experience with this, maybe you could point me...
  10. D

    Resurrecting a waterlogged mep-803A

    You mentioned starting fluid. That is a big no-no on these smaller units. I just got a 002 repaired and started after what appears starting fluid was used on it. Piston ring lands on #1 and #2 rings destroyed. Was lucky enough to find two serviceable used pistons. Good luck on your efforts. David
  11. D

    Next 002 Issue

    I have a couple of other threads documenting getting two 002's going that I purchased in a private sale. From rotating diodes to starter/flywheel replacement, and general cleanup, it has been a challenge. After diagnosing low compression on one cylinder (325 vs 465 psi), I pulled the head. This...
  12. D

    Mep 002a Starter Issues

    I worked on Capitol Hill and had an employee that was dyslexic. Didn't know about it until I caught him taking service work orders home for his wife to read to him. He does have a fantastic memory. From then on, I took him in my office and discussed each work order he was assigned. He can go all...
  13. D

    Mep 002a Starter Issues

    Looks like someone went to town on this one. Flywheel teeth were rounded over and starter teeth were half gone. Wonder how many times they tried to start it? Lends some credence to Guyfang's follow through with troubleshooting comment. David
  14. D

    Mep 002a Starter Issues

    guyfang, I do have 24 volts on one wire that was attached to P16. Compared this S7 to another from a donor machine. The copper strip seems stiffer on the donor S7 (contacts have more "snap"). Everything else on the switches looked the same. Both plunger's were the exact same length. Cleaned up...
  15. D

    Mep 002a Starter Issues

    Guyfang, The only way there would be voltage at S7 would be the switch is open and S1 is in start position? Correct? David
  16. D

    Mep 002a Starter Issues

    Guyfang, Appreciate the comeback. My unit does not have the cannon plug (P16?) to disconnect the S7 switch. It has been cut and replaced with crimp-on butt connectors. I have direct continuity from tb4-3 through S7 to ground when genny is off. When starting, it acts like the S7 contacts are...
  17. D

    Mep 002a Starter Issues

    Well, I am back into it this AM. Jumped S7 contacts and starter runs correctly every time I tried it. With TM in hand, cleaned S7 contact and set to just closed (w/continuity). Started unit and disconnected circuit. Checked with .040 feeler gauge and only had to adjust point gap 1/8th of a...
  18. D

    Mep 002a Starter Issues

    Bypassed K3 negative circuit by jumping TB4-3 around S7 to battery negative. Starter runs like it should. I had taken the speed switch out and looked at it before. Will pull out again and check it out. Also wiring could be suspect. Got to run for now. Many thanks for the support. David
  19. D

    Mep 002a Starter Issues

    Well, that one flopped. Jumped starter solenoid with 24 v. Starter runs as long as I hold the wire on it. Spins at a good rate. In my original post, I held in K3 which energizes K6 and the starter will run with no problems. Back to somewhere in the control circuit.... What's the purpose with the...