Jerry, I wouldn't be overly concerned about 42VAC. Since it's not actually charging the battery, the output may be open circuited and running a little higher than when it's operating properly. 42 is only 20% higher than 35, and in the electrical world, 20% isn't usually anything to be alarmed...
I actually make one for another application that is very similar, except for the 24V part. If there's really a need for them I could put it on the to do list.
I'll never get synthetic oil for my compressor again. You can't use a lot of accessories like water separators with sight gauges, because the oil wrecks the plastic. I had one sight gauge blow off and start hissing loudly one day. When I called Gilkerson I got the news about synthetic oil.
The extra fuel that's returned to cool the injector pump is extra fuel pumped by the injector pump itself, not the 24V supply pumps. There is no return line for those, they just stop pumping when their flow is blocked.
If you have no flow of fuel to the injector pump, the engine isn't going to run. But both main pumps not working sounds like a wiring or switch problem. If both pumps really are bad, you can use the auxiliary pump to replace one of them and get the unit running.
When I was going to school at the U of MD, I would sometimes browse the stacks of the engineering library, mainly when I should have been studying. I was amazed to see complicated analyses of electric motors and generators, including calculus and differential equations, in journals dated from...
Absolutely, sorry for the goof, and thanks for fixing it! For sine waves, multiply RMS voltage by √2 to get peak voltage. Divide peak voltage by √2 (or multiply it by 1/√2 =approx .707) to get RMS voltage.
Specifically it has to be a sine wave for the √2 (approx. .707) factor to apply. For example, triangular waves, even if symmetrical, use √3 instead.
Edit: As stated below, √2 is approx. 1.414!
Only for square wave AC. Modified sine wave AC is usually square pulses with some time at zero volts in between, so peak voltage is greater than RMS.
For a sine wave, V(peak)=V(rms)(√2), so for 120V AC, the peak voltage is 169.7V, and peak to peak is 339.4V. AC voltage is almost always...
This phenolic epoxy coating has been used on a lot of badly rusted and/or leaking motorcycle tanks with great success. It's thicker than some of the other coatings like Kreem and POR-15, and resists all the common fuels like diesel and today's gasoline...
I vote for the (gentle) hammer-on repair or the drill-and-tap repair because the other methods heat up the post quite a bit. It's supported by plastic and that seal needs to be maintained or you have a mess of seeping acid. If it still seals after the mishap, heating it again might be asking...
Yeah, I've seen a little of what you posted myself. The web is full of self-proclaimed experts giving advice, so I guess the military generator information is about on par. I can tell you that in the year that I've had my 003A, I've used it to power the house monthly, and for real multi-hour...
To my surprise, the Walmart batteries I've gotten in the last 6 or 8 years here in NC have been amazingly good. I have to say that all batteries I've gotten in my 55 year life have been a crap shoot though.