Search results

  1. Suprman

    Problem with 3116 fan? Heard a clink clink then saw these pieces

    It's a common fan clutch.
  2. Suprman

    Camp Lejune hvac trailer grab n stash somewhere off base

    Ok thanks. Yup Lejune is Thursday mornings only. Felix said he would meet at the gate to get someone right in. I will let you know I am trying to get a hauler to pick it up. Not having much luck. That whole 2 hours a week window make it hard.
  3. Suprman

    Camp Lejune hvac trailer grab n stash somewhere off base

    Not feelin the love here
  4. Suprman

    Fort Drum GL Chaos

    Put together all the documentation and send to the NY Atty generals office. I have a feeling they would do something about it.
  5. Suprman

    M923A2 CTIS Problem

    The system does a pressure test to look for leaks and to determine tire pressure. If it senses high pressure it sends 12psi to hold open the wheel valves and dump. If the wheel valves dont have that continuous 12psi they will not stay open to dump. A bad hub seal will trick the pressure test but...
  6. Suprman

    Camp Lejune hvac trailer grab n stash somewhere off base

    Anyone with base access?
  7. Suprman

    M923A2 CTIS Problem

    Mechanical system. Low pressure holds open wheel valves to dump. Fill pressure diluted via leak and the wheel valves see low pressure and are tricked into dumping. Very common.
  8. Suprman

    HVAC AC refrigerant recharge maintenance guidance needed

    I looked up the comp and figured it out. Hooked up the vac pump for 45min. Let it sit for another 45min and gages have held vacuum.
  9. Suprman

    MEP805A regulator

    I know I have the 60s. The 30s and 60s are marked as such. Are they interchangeable?
  10. Suprman

    M923A2 CTIS Problem

    Sounds like a bad hub seal or small air leak somewhere thats not enough to trip a fault but dilutes the fill pressure by the time it makes it to the wheel valves.
  11. Suprman

    HVAC AC refrigerant recharge maintenance guidance needed

    Here is the pic. Which is low which is high port. On right of unit.
  12. Suprman

    HVAC AC refrigerant recharge maintenance guidance needed

    Its an applied unit. Is suction the low side?
  13. Suprman

    HVAC AC refrigerant recharge maintenance guidance needed

    One connection looks like it goes to the top of the ac compressor and one the bottom line. Both lines look around the same size. Which is low and high?
  14. Suprman

    A3 4x4

    Just get a m1078 and make it into a dump bed.
  15. Suprman

    MEP805A regulator

    I think I have the 30k trc kit.
  16. Suprman

    I have joined the club ! And yes I have lost my mine !

    Looks nice. I don't think the original headlight location is bad. The original bulbs are a bit dim. If you are going off roading at night all that extra light can't hurt. Take a pic at night with them on.
  17. Suprman

    mep-802/803 voltage regulator adjustment pot

    I set the front panel pot to its center position then adjust the regulator to the voltage I want. If it's not right to begin with. If it's ok from the start no need to touch it.
  18. Suprman

    MEP805A regulator

    Well that answers why the regulator kits state you must use all components when changing the regulator. They should have put specifically why on the note.
  19. Suprman

    HVAC AC refrigerant recharge maintenance guidance needed

    I believe the unit was working fine before the military purged it for disposal. I think they just suck out the r22 since it's not environmentally friendly. If I had a local HVAC guy that was reasonably priced I would have him come out.
  20. Suprman

    HVAC AC refrigerant recharge maintenance guidance needed

    Is the top or bottom connection the low side. They are both the same size and not marked. The tm does not specify which is the low. Can I buy a bottle of nitrogen? How do I pressurize it into the system?
Top