  1. mistaken1

    20 psi oil pressure on mep 002a

    The low oil pressure cutout switch is set at 14-15 lbs. What does the manual say: From TM 5-6115-584-12 MEP-002A Maintenance Manual - Change 6 - Page 2-3 : Same manual page 2-5 Same manual table 3-2 Same manual page 4-37
  2. mistaken1

    mep-002a ground post

    And here: Connecting MEP to house Connecting MEP to house
  3. mistaken1

    To Bond Or Not To Bond

    Check these threads and links: Connecting MEP to house Connecting MEP to house
  4. mistaken1

    Glow Plug process overhaul

    Just an FYI. In a fully functioning stock system you will measure a full 24V at that glow plug relay when it is not energized. The resistor will only drop the voltage when current is flowing through it to the glow plugs. If the glow plug relay is energized and you are reading 24V at the glow...
  5. mistaken1

    Glow Plug process overhaul

    What does the TM say? From TM 9-2320-289-20 Unit Maintenance Manual CUCV: I would replace them with new ones and keep the old ones as emergency spares.
  6. mistaken1

    MEP-004a 15kw rewired 1 phase, connecting to home. Transfer Switch Question/Advice

    As I understand it if you are doing automatic transfer and automatic generator start then the generator has to be sized for the full load or if not sized for the the full load you must to have automatic load shedding. If the transfer is manual then you can undersize your generator and do manual...
  7. mistaken1

    It Is Alive!!!

    Congratulations.
  8. mistaken1

    Glow Plug process overhaul

    You can download the manuals in the resources section at the top of the page. You really need to change all of the terminals and glow plugs at the same time. The bypass switch just activates the glow plug relay so 10A to 20A will be fine. Make sure it is a momentary switch. Conductive grease...
  9. mistaken1

    Possible power inverter under radio rack?

    And if it is 12V then you can use the positive and negative bus to power an inverter. I highly recommend either a fusible link or a fuse between the bus and your inverter.
  10. mistaken1

    M101 dump trailers ???

    The business people call it marketing ...... the politicians call it spin ..... I call it misleading at best.
  11. mistaken1

    no power low idle smoke

    From the 20 manual I assume none of these things cured the problem.
  12. mistaken1

    no power low idle smoke

    White smoke = unburnt fuel Black smoke = lack of air As I understand the diesel they need air. Basically the air flow is always wide open (or should be) and the throttle controls the amount of fuel injected (unlike a gas engine where the throttle controls the air flow). You checked the...
  13. mistaken1

    CUCV Help

    White smoke could be steam but is typically un-combusted (is that a word) fuel. Black smoke is typically not enough air. Compression tests on each cylinder? Valve not fully seating preventing full compression and consequently combustion? Are you losing coolant without any visible leaks?
  14. mistaken1

    Batterys

    I prefer 12 volt lead acid batteries. 750 CCA or bigger. :lol:
  15. mistaken1

    M1009 Starter system

    So the doghead relay is switching 12V to the 12V starter solenoid. Check the grounds and all the wires at the terminals. Wires and connections can be corroded and measure okay with a meter but when a large amount of current starts to flow (like to turn a starter motor) those high resistance...
  16. mistaken1

    M1009 Starter system

    You now have a 12V starter (motor and solenoid) with a doghead relay sending 24V to the 12V starter solenoid?
  17. mistaken1

    My new ignition switch has an accessory stop but...

    A key switch in the run position without the engine running can damage the glow plugs in stock systems or cause the glow plugs to drain the battery in 12V fed systems (assuming the engine is cold and controller card is functioning properly). If your glow plug controller was eliminated from the...
  18. mistaken1

    Glow plug testing questions

    Could be glow plugs or quite possibly and air leak in the fuel system. Particularly at the stock filter base.
  19. mistaken1

    Progress being made...I see light at the end of the tunnel...

    Shops loaded with high dollar tools are nice!
  20. mistaken1

    new guy

    Welcome to the site. You can download the Army repair manuals here on this site as well as several others. Check the CUCV wiki for lots of good info.