  1. Scoobyshep

    MEP-003A

    So its hard to start when hot? What color smoke? Sprayed the selector switch with what? assuming gauge selector.
  2. Scoobyshep

    Hello from CT, M831A Question

    Its too bad they couldn't come up with a more mutually beneficial resolution
  3. Scoobyshep

    Hello from CT, M831A Question

    What I would do and what another would do re probably 2 different things.
  4. Scoobyshep

    Hello from CT, M831A Question

    Want to no, tolerate a set amount of bullshit when the alternative companys are limited? Yes to a degree Sent from my SM-G973U using Tapatalk
  5. Scoobyshep

    Hello from CT, M831A Question

    They will lock your account Sent from my SM-G973U using Tapatalk
  6. Scoobyshep

    MEP-803A looks brand new - no reset tag

    I have a 30 year old 004 with 38 Sent from my SM-G973U using Tapatalk
  7. Scoobyshep

    MEP-803A looks brand new - no reset tag

    Its entirely possible its accurate, sometimes they just never got deployed and sat in a warehouse for years. Sent from my SM-G973U using Tapatalk
  8. Scoobyshep

    Damage to 802 from non standard voltage/frequency

    If you are that concerned, perhaps a buck transformer? Sent from my SM-G973U using Tapatalk
  9. Scoobyshep

    Damage to 802 from non standard voltage/frequency

    Frequency is a function of rpm. So no harm there. Might be a higher current on the field windings but I wouldnt think it would harm it. Sent from my SM-G973U using Tapatalk
  10. Scoobyshep

    Yanmar L70 Diesel Kit for MEP-016

    Id be surprised if 12 volt would spin a 24 volt starter fast enough. Sent from my SM-G973U using Tapatalk
  11. Scoobyshep

    Yanmar L70 Diesel Kit for MEP-016

    If you can find the electric components (starter, alt, solenoids etc) in 12 volt. Remember half the starting voltage is double the starting current. Sent from my SM-G973U using Tapatalk
  12. Scoobyshep

    Converting 416v output to 480v output

    You can still get a delta service. The more common reason buildings end up with a delta is utility being cheap, open delta can me made with 2 legs of primary, where wye needs all 3 legs.
  13. Scoobyshep

    Converting 416v output to 480v output

    Its just a rating, Alot of motors are rated at 440 or 460 to account for service fluctuations. One plant I worked at ran at 500v during the day and 450 at night, this was because they were at the end of the feeder loop and when people were getting home the draw would be higher.
  14. Scoobyshep

    Woke up to Orange Sun, Raining Ash & No Power

    If you are gonna run a last ditch effort, why not bypass the safety circuits as well? Fire pumps are setup like this.
  15. Scoobyshep

    Converting 416v output to 480v output

    On top of that, most 480 loads will run on 460, they just draw a bit more current. Sent from my SM-G973U using Tapatalk
  16. Scoobyshep

    Converting 416v output to 480v output

    If youre trying to hit 480 line to line then the lone to ground should be 277. So 265/460 is fairly close Sent from my SM-G973U using Tapatalk
  17. Scoobyshep

    Woke up to Orange Sun, Raining Ash & No Power

    So fun fact here, the limitations of a generator head (much like an electric motor) are mainly based on how much heat can be removed and keeping the windings below the damage temperature. We have a few motors at work that are rated at 2700 hp, but we are pushing about 4000 hp out of them because...
  18. Scoobyshep

    Woke up to Orange Sun, Raining Ash & No Power

    If it sounds like a controlled stop, it isnt a severe overload, those more or less drag the engine down.
  19. Scoobyshep

    Woke up to Orange Sun, Raining Ash & No Power

    Imbalance shouldn't matter, as long as you dont exceed the maximum