I've searched through the forum here and I've not been able to find this problem discussed yet.
On my MEP-003a I started it a couple of days ago to load test it. Everything started and ran fine except for the voltage. The voltage fluctuated above the setpoint. It didn't just bounce around but...
I'm debating on whether I put a light on there or maybe a small pressure gauge. The more I think about it the more a gauge makes sense.
Assuming I can work it in. I think I could if I updated it to the digital gauge set for current and voltage... Hm..
I have an ASK on my generator so its impossible to see the oil pressure gauge to know when to release the start switch. I've released it too soon a number of times and have had to start it again. In an effort to not hold it any longer than necessary but long enough for oil pressure I've...
I personally plan to install redundant filters when I change mine over. The filter he is using is a water separator as well as a particulate filter. Other than the extra piece of mind you get with dual filters is there another reason to be concerned about a single filter? My jetta tdi has only...
Hi,
I think a good place to start is at the top of the main page for this section. There are a few stickys as well as a link to a wiki.
Is there anything specific you are trying to find out?
Good info. I'll be curious to see how it looks when you have it put together.
I have the LED strips all over the house, the back porch, and the outbuilding. So far I've not had issues with the PWM dimmers being a problem on HF. The controllers I'm using run at 40khz. The CFL lights in the...
Thats interesting to go to that length to shield the LEDs. What frequency is the controller operating at?
Am I understanding it correctly that the entire strip will be fully enclosed in a vinyl cover? You may want to test that to make sure you have enough thermal dissipation.
There is and answer. I hope this isn't too long winded. I have been known to over explain things.
LEDs generate much less heat relative to their light output than conventional lamps but still generate heat. The key difference is how that heat is carried away from the light. With a normal...
I use a lot of the LED strips for any number of lighting tasks. One bit of advice I would offer is to make sure they are attached to something that can act as a heatsink. This is especially true if you are driving them near their current limits. Otherwise their white point will shift and their...
Yea, Each corner post burred in the ground on one end and standing to the desired elevation height for the generator. The same method as building a deck.
I used the original terminals. You can add a hasp and a lock if you need.
I considered installing a conduit bushing in the side of the box and doing exactly what you are considering. In the end it was more effort for very little gain. The way the terminals are in there it doesn't leave a lot...
Buy short pieces then use a set of split bolts sized to join #10 to #6.
You'll want to install a box with a 30a breaker between the generator and the #10 cable or reset the trip on the generator breaker for 30a.
The lugs are too large for 10 gauge. Based on the output of the generator you need to run at least 6 gauge. The 6 gauge wire I ran between the lugs and the outlet tightened up just fine.