  1. N

    UL listing for mep 803a or 831a?

    So my choices right now are : 120v 15 amp fuse that is UL listed + add a new gfci receptacle ($5 plus $18) Or Replace gfci box with an updated UL listed one for $56 plus run new 12awg wire (new ones are 20 amp) What do you guys think ? Problem is the current gfci isn’t UL listed Sent...
  2. N

    Heating a seized engine. Ideas?

    Had good success with plain old diesel over 2 months and working it back and forth with a bar Sent from my iPhone using Tapatalk
  3. N

    UL listing for mep 803a or 831a?

    I think the inspector thought the gfci just measured disparity in current in and current out and neglected to see that there is also a resettable fuse for overload protection. The inspector wanted a fuse between gfci and generator for current protection and because the old version of the gfci...
  4. N

    UL listing for mep 803a or 831a?

    Also do you happen to know if there is an inline fuse on the 803a gfci box ? Sent from my iPhone using Tapatalk
  5. N

    UL listing for mep 803a or 831a?

    I like the cement idea Where is the in line fuse that protects the gfci box ? It is not on the wiring diagram and I cannot locate it physically. That would solve adding a fuse ! Sent from my iPhone using Tapatalk
  6. N

    UL listing for mep 803a or 831a?

    Hi everybody, had inspection done. A couple things were mentioned as needed for conformity the gfci box (has no certification on it (ul, etc) and is required to have an inline fuse. A few other small things, load box (way to lock it so loads are not exposed) Was suggested that I get an...
  7. N

    Finally bought a MEP-831a

    Hope you will enjoy it, I am happy with the ones I received, no more dinking with the GAC one (I did order a GAC replacement unit when I first started and it is still going well) Any thoughts about adding an external silencing muffler to quiet the set down further? (while keeping the 2169b std...
  8. N

    Lister/Onan LPW2/DN2M

    I Highly recommend parts from these guys, much better than china production https://www.mayidiesel.com/
  9. N

    AcuTemp Refrigerator

    Could lack of refrigerant be a problem on these units with them sitting for so long without running?
  10. N

    MEP831A DC charging unit problem

    I will be checking a couple other units to see the zip tie condition
  11. N

    MEP831A DC charging unit problem

    Problem found, see broken zip tie allowing vibration. Pending reinstall after fix and confirmation of working. DA - I would very much want a manual 24v charger to apply voltage as needed from 110-120. I would expect all our power supplies are waiting to die from the torridal coil...
  12. N

    MEP831A DC charging unit problem

    Thanks DA for your input. Any idea on a replacement?
  13. N

    MEP831A DC charging unit problem

    Hello everybody, What should the current range be on the output of the DC charging unit? Problem observed is following: When the battery is removed from a running unit it will not run, and when a battery is connected, it is not able to keep the battery stabilized and runs it down...
  14. N

    AcuTemp Refrigerator

    It seems like a sealed water bottle with big thermal mass would be much harder to cool than a larger open mouthed container i.e. mixing bowl full of water. I'm hoping to use mine to make ice in trays and I expect these would freeze very quickly compared to a sealed item with a certain depth to it.
  15. N

    AcuTemp Refrigerator

    Cookie monster likes data cookies! Nom nom nom nom! Sorry, seriously, thank you for doing this. Looking forward to the next cooler test to see if uniform. Regarding the unit for data - I see it is named bbq - do you bbq remotely?? That is great if so.
  16. N

    UL listing for mep 803a or 831a?

    Does anyone know if there has ever been a UL listing or any safety testing done that would satisfy a utility / insurer of a property that is powered by said generator? (mep 803a or 831a)
  17. N

    AcuTemp Refrigerator

    Can anyone confirm what battery model # they have used that successfully fits in without modifying the tray?
  18. N

    AcuTemp Refrigerator

    Anybody know the battery size? Or a commercial part number? I found below:L 2 v, 21 amp hour total capacity; 17.8 x 7 x 17 cm; 5.9 kg; 7 x 2.9 x 5.5 in.; 15 lbs; for use with vaxicool part number vxc-2 or vxc-sp-dd1. Anyone have photos of the old battery? Rusty? It will go in the trunk in...
  19. N

    Break in Oil for piston replacement?

    guys here have mentioned the john deere break-in oil. where did you get pistons and rings? how dear were they