• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. D

    Working MEP Gensets on GL?

    Most of the trailers I've seen have had tires that looked good from a distance, with good tread, but did not pass close inspection. I always bring a farm jack and at least two spares when recovering a GL trailer. I say be prepared and inspect them closely before you take them on the highway.
  2. D

    mep017 old type voltage reg. diodo id

    You can use the existing front panel variable resistor (pot) with the SX460. It should be a 750 Ohm pot. To set it just put the front panel variable resistor in the middle of its travel and use the volts adjustment on the SX460 to set the output to 120V or 240V or whatever your target output...
  3. D

    mep017 old type voltage reg. diodo id

    I, personally, prefer the SX460. It has low frequency cutout and is a more modern design. You can put new diodes in a VR but you still have other old components in there. On the other hand the old stuff was well made and robust.
  4. D

    mep003 gen parts

    Groovy. I have a project in Houston in coming weeks. Maybe I'll see if he has a stator for my 003A.
  5. D

    Working MEP Gensets on GL?

    I'm like 10 for 10. Most have been 3kW Diesels, though. One 003A runs but has crusty fuel tank and bad DC charging stator. Most just needed fuel system flush and minor repair like a cable or something. One had fuel and oil, but no battery, and fired up immediately.
  6. D

    MEP -004a. DC circuit breaker issues

    You may have shorted something like the glow plug harness or injector solenoid. I only have a general idea of the workings of these gens.
  7. D

    MEP-002A acquisition

    I'll say it: Buy one of his oil filter adapter kits. If I didn't have a lathe I probably would, too.
  8. D

    MEP -004a. DC circuit breaker issues

    If you made sparks you need to find and fix the damage. If there is a fuse it should be shown somewhere in the TM. There isn't usually a fuse between a battery and a circuit breaker, though.
  9. D

    MEP-016b low output voltage

    I think I have a spare reg around here if you end up needing one. I have two 701As around here if you need them, too. I'll make you a deal on both. First, check the convenience outlet voltage with your multimeter. You may just have a wacky panel gauge. Next, as with all things...
  10. D

    Frequency Transducer compatibility

    These are hard to beat for $20. They don't match the other components. But, sometimes function before fashion is appropriate. Diesel Generator easy voltage and frequency meter | eBay The pic shows two, one reading V and one Hz. You only need one and you push the button to toggle between V...
  11. D

    WTB 24 volt gen batt

    Battery Warehouse had them last time I talked to the lady. She can ship them dry. 337-462-1352 I think they were like $90 dry.
  12. D

    How did you pick up / move your MEP 002

    I haven't been to Hooks, yet. The lady at Ft. Polk is skilled with her forklift. The guy at Eglin is good. The guys at Camp Shelby are good, too.
  13. D

    How did you pick up / move your MEP 002

    I had a MEP-003A loaded into the bed of my Toyota Tacoma Prerunner by the guy with the forklift at the GL site. I unloaded it at a friend's shop with his forklift. I've used an engine crane to unload my 1000+ pound Kubota generator before. I could pick it up, turn it sideways, and lower it on...
  14. D

    MEP -003a. Gauge issues

    There is a rotary switch to change the gauge to read different outputs. Have you tried different switch settings?
  15. D

    MEP 017a Low Voltage output ?

    Windings do fail. They can go short or open. Sometimes they check out OK (like 0.7 Ohms) and then short or open under load. I have an 003 with a bad stator.
  16. D

    need help with starter for my 89 3 kw 24v generator

    How full is the tank? There is a low fuel shutdown to keep it from surging when the fuel runs out. You can reach in the tank and lift up on the float. Is the solenoid shutting it down or is it just starving for fuel? I have a 701A that had a loose part in the middle fuel pump, not the...
  17. D

    MEP 701A parts source

    Apples/oranges. 701A is a single cylinder 3kW, 002A is a twin cylinder 5kW. 701A weighs about 535 pounds, 002A over 1000lbs. 701A is a 3600RPM machine, 002A is an 1800RPM machine, but the 3600RPM engine has good efficiency, too. I prefer the MEP-016D, which is the MEP-016A(originally gasoline)...
  18. D

    MEP 021D Help

    Look for a tag on the gen head, right behind the motor. I'm pretty sure my 016E has a tag that says 3kW 60Hz. It may just have a NSN number. If so, you can look that up. See pic. What does that tag say?
  19. D

    MEP 021D Help

    Look at the red label on the voltage regulator. It should have wiring instructions for 3kW, 5kW, 60Hz, 400Hz, etc. The red, black, and white wires should correspond to something on the chart on the red label on the voltage regulator. I'll bet you'll find it is set for 3kW 400Hz.
  20. D

    MEP 002/3 a fuel pumps...

    Lift pump, auxillary pump, injector pump, how many do you need?
Top